Friedrich MR09C1F User Manual

Page 2

Advertising
background image

Ÿ

*

&

§

+

£

%

^

¡

º

ª

(

)

¢

_

5

6

4

7

8

OPERATION

TIMER

SUPER QUIET

SWING

=

A B

D

C

9

3

1

E

F

G

2

Fig. 5

Fig. 1

Fig. 2

Fig. 3

Fig. 4

This figure shows the control display when all indicator lamps are on. It may differ from the actual display.

Fig. 7

Fig. 8

Fig. 6

En-1

CONTENTS

SAFETY PRECAUTIONS .................................... En-1

NAME OF PARTS ................................................ En-2

FEATURES AND FUNCTIONS ............................ En-3

PREPARATION .................................................... En-4

OPERATION ........................................................ En-5

TIMER OPERATION ............................................ En-7

SLEEP TIMER OPERATION ................................ En-8

ADJUSTING THE DIRECTION OF

AIR CIRCULATION .............................................. En-9

SWING OPERATION ......................................... En-10

MANUAL AUTO OPERATION .......................... En-10

CLEANING AND CARE ..................................... En-11

TROUBLESHOOTING ....................................... En-12

OPERATING TIPS .............................................. En-13

SAFETY PRECAUTIONS

Do not attempt to install this air conditioner by yourself.
This unit contains no user-serviceable parts. Always consult authorized service per-

sonnel for repairs.

When moving, consult authorized service personnel for disconnection and installa-

tion of the unit.

Do not become excessively chilled by staying for lengthy periods in the direct cooling

airflow.

Do not insert fingers or objects into the outlet port or intake grilles.
Do not start and stop air conditioner operation by disconnecting the power supply

cord and so on.

Take care not to damage the power supply cord.
In the event of a malfunction (burning smell, etc.), immediately stop operation, dis-

connect the power supply plug, and consult authorized service personnel.

If the power supply cord of this appliance is damaged, it should only be replaced by

the authorized service personal, since special purpose tools and specified cord are
required.

Provide occasional ventilation during use.
Do not direct air flow at fireplaces or heating apparatus.
Do not climb on, or place objects on, the air conditioner.
Do not hang objects from the indoor unit.
Do not set flower vases or water containers on top of air conditioners.
Do not expose the air conditioner directly to water.
Do not operate the air conditioner with wet hands.
Do not pull power supply cord.
Turn off power source when not using the unit for extended periods.
Check the condition of the installation stand for damage.
Do not place animals or plants in the direct path of the air flow.
Do not drink the water drained from the air conditioner.
Do not use in applications involving the storage of foods, plants or animals, precision

equipment, or art works.

Do not apply any heavy pressure to radiator fins.
Operate only with air filters installed.
Do not block or cover the intake grille and outlet port.
Ensure that any electronic equipment is at least one metre away from either the in-

door or outdoor units.

Avoid installing the air conditioner near a fireplace or other heating apparatus.
When installing the indoor and outdoor unit, take precautions to prevent access to

infants.

Do not use inflammable gases near the air conditioner.

DANGER!

CAUTION!

TYPE

COOLING MODEL

TYPE

MODÈLE REFROIDISSANT

TIPO

MODELO REFRIGERACIÓN

MODEL

INDOOR UNIT

MODÈLL

UNIDAD INTERIOR

MODELO

UNITÉ INTÉRIEURE

OUTDOOR UNIT
UNIDAD EXTERIOR
UNITÉ EXTÉRIEURE

MW09C1F

MR09C1F

ESPECIFICACIONES

ALIMENTACIÓN ...................................................................................................................................... 115 V~60 Hz

REFRIGERACIÓN

CAPACIDAD ....................................................................................................................................... 12.300 BTU/h
ENTRADA DE ALIMENTACIÓN ................................................................................................................. 1,06 kW
CORRIENTE ..................................................................................................................................................... 9,8 A

TYPE

COOLING MODEL

TYPE

MODÈLE REFROIDISSANT

TIPO

MODELO REFRIGERACIÓN

SPECIFICATIONS

POWER SUPPLY ...................................................................................................................................... 115 V~60 Hz

COOLING

CAPACITY ............................................................................................................................................. 9,700 BTU/h
INPUT POWER ............................................................................................................................................ 0.82 kW
CURRENT ........................................................................................................................................................ 7.6 A

FICHE TECHNIQUE

ALIMENTATION ....................................................................................................................................... 115 V~60 Hz

REFROIDISSEMENT

PUISSANCE FRIGORIFIQUE ............................................................................................................... 9.700 BTU/h
PUISSANCE ABSORBÉE ............................................................................................................................ 0,82 kW
INTENSITÉ ...................................................................................................................................................... 7,6 A

ESPECIFICACIONES

ALIMENTACIÓN ...................................................................................................................................... 115 V~60 Hz

REFRIGERACIÓN

CAPACIDAD ......................................................................................................................................... 9.700 BTU/h
ENTRADA DE ALIMENTACIÓN .................................................................................................................. 0,82 kW
CORRIENTE ..................................................................................................................................................... 7,6 A

MW12C1F

MR12C1F

MODEL

INDOOR UNIT

MODÈLE

UNIDAD INTERIOR

MODELO

UNITÉ INTÉRIEURE

OUTDOOR UNIT
UNIDAD EXTERIOR
UNITÉ EXTÉRIEURE

FICHE TECHNIQUE

ALIMENTATION ....................................................................................................................................... 115 V~60 Hz

REFROIDISSEMENT

PUISSANCE FRIGORIFIQUE ............................................................................................................. 12.300 BTU/h
PUISSANCE ABSORBÉE ............................................................................................................................. 1,06 kW
INTENSITÉ ...................................................................................................................................................... 9,8 A

SPECIFICATIONS

POWER SUPPLY ...................................................................................................................................... 115 V~60 Hz

COOLING

CAPACITY ........................................................................................................................................... 12,300 BTU/h
INPUT POWER ............................................................................................................................................ 1.06 kW
CURRENT ........................................................................................................................................................ 9.8 A

Advertising
This manual is related to the following products: