Product specifications – Fedders Cased A-Coil AC1A Series User Manual

Page 2

Advertising
background image

Product Specifications

2

Specifications subject to change without notice.

COIL SPECIFICATIONS

MODEL

NUMBER

TYPE

AIR

FLOW*

FLUSH
FIT TO

FURNACE

WIDTH

CFM

RANGE

FACE

AREA

SQ. FT.

FINS

PER

INCH

TUBE

O.D.

NUMBER

OF

ROWS

NUMBER

OF

CIRCUITS

LINE

CONNECTIONS O.D.

LIQUID

SUCTION

AC1A024A

U, D

14.5, 16

600 - 900

4.00

14

3/8"

2

4

3/8"

3/4"

AC1A030A

U, D

14.5, 16, 17.5, 20.5

800 – 1,250

3.11

14

3/8"

3

6

3/8"

7/8"

AC1A036A

U, D

14.5, 16, 17.5, 20.5

1,000 – 1,400

4.00

14

3/8"

3

6

3/8"

7/8"

AC1A042A

U, D

17.5, 20.5

1,300 – 1,500

4.89

12

3/8"

3

6

3/8"

7/8"

AC1A060A

U, D

17.5, 20.5, 22

1,400 – 1,900

5.80

12

3/8"

3

6

3/8"

1

7/8"

2

MODEL

NUMBER

STATIC PRESSURE DROP THROUGH WET COIL & HOUSING (INCHES WATER COLUMN / CFM)

600

700

800

900

1000

1100

1200

1300

1400

1500

1600

1700

1800

1900

AC1A024A

0.10

0.11

0.12

0.13

AC1A030A

0.15

0.17

0.19

0.21

AC1A036A

0.19

0.20

0.22

0.23

0.24

AC1A042A

0.15

0.17

0.18

0.21

AC1A060A

0.21

0.23

0.23

*U = Upflow Applications. D = Downflow Applications.
1 = Requires a 1/2" - 3/8" reducer.
2 = Requires a 1 1/8" - 3/8" reducer.

Airflow configurations (drawings showing different installation configurations)
This product is ARI certified when matched with other Fedders products.

Advertising