WARNING

All electrical work must be done in accordance with local and/or national electrical codes as
applicable. For safety, this product must be earthed. If you are unfamiliar with methods of
installing electrical wiring, employ the services of a qualified electrican.

Turn off power at service entrance before installing wiring or servicing this product.

The canopy is heavy, overall weight 65 lbs (29kg). Please ensure adequate care when
installing the canopy to prevent personal injury.

The canopy must be installed onto a solid wall or solid studs.

NOTE: Stainless steel and iridium is very easily
damaged during installation if abraided or knocked by tools.

Read the instructions before starting the assembly.
Remove the filters to allow access to wall mounting holes.

The unit is designed for 2290 to 2690mm (7’ 6” to 8’ 10”)
high ceilings. The chimney is telescopic and is designed for
615 to 895mm (24~3/16” to 35~1/4”) adjustment.

Ascertain the desired installation height of the canopy.
NOTE: Installation height ranges from 610 to 760mm
(24” to 30”).

DUCTING: Ducting accessories are not supplied.
The air outlet from the motor requires 150mm (6”) round
ducting which requires 160mm (6~5/16”) diameter hole
in the ceiling.

lbs

lbs

Ceiling height

2290 to 2690mm

(7’6” to 8’10”)

Installation height

610 to 760mm

(24” to 30”)

Cooking surface

914mm (36”)

P R E - I N S T A L L A T I O N

I N S T A L L A T I O N O F U N I T

T h i s a p p l i a n c e must be positioned so that the electrical
plug is accessible.

Care and attention should always be taken when cooking with oils, alcohol, etc,
which give off flammable vapours. Pre-used oil is especially dangerous in this
respect. Do not use an uncovered electrical grill.
Particular care must be taken with grease filters which must be periodically
cleaned, at least every two months. Remove the grease filters and wash them
either by hand or in the dishwasher using mild detergent.
U s e l u k e w a r m w a t e r a n d m i l d d e t e r g e n t t o c l e a n s ta i n l e s s s t e e l / i r i d i u m
components. In high humidity and coastal environments, cleaning should be
carried out frequently. CAUTION: Never use abrasive or oil based liquid
cleaners.

INSTALLING MOUNTING BRACKET

Align the centre of the installation bracket with the centre
of the cooking surface (recommend to use plumb bob).
Place the flat/horizontal surface of the mounting bracket 215mm
(8~1/2”) above the installation height (dia.1).
Ensuring the mounting bracket is level, mark and drill the holes
in the wall.
Use the screws and plugs provided to attach bracket.

INSTALLING CHIMNEY BRACKETS

Cut cornice to suit the chimney cover.
Align the centre of the chimney bracket with the centre of the
cooking surface.
Mark and drill the holes in the wall and ceiling.
Use appropriate mounting screws or anchors.

INSTALLING THE CHIMNEY

A rubber extrusion has been provided to hide any irregularities between
the chimney and the canopy/ceiling, it is fitted by simply pushing it over
the top and bottom visible edges of the chimney. This steel edge may be
sharp so care must be taken to avoid damage to fingers. If desired this
extrusion may be omitted from the assembly.
Remove the protective plastic film from the chimney. Prior to mounting
the chimney, determine the height required on the chimney. The height
can be adjusted by changing the screw on the back lip (dia.2). Do not
tighten the screws because the chimney needs to slide up when
installing the canopy. Mount the chimney to the ceiling bracket using
the screws provided .

INSTALLING THE CANOPY

Ensure the filters are removed from the canopy.
Hang the canopy onto the installation bracket.
Align the canopy so it is central to the cooking surface and lines
up with the chimney cover.
Mark out the position of the two safety screw holes located on
the back panel.
Remove canopy, drill the safety screw holes and fit wall plugs.
Refit the canopy to the wall and secure using the appropriate
mounting screws (dia.3).
Remove protective plastic film from the canopy and filters.
Refit the filters to the canopy.

215mm

dia.1

215mm

inst

allation height

cooking surface

dia.2

dia.3

C A N O P Y O P E R A T I O N

Thank you for purchasing a quality stainless or iridium canopy rangehood.
We have a high standard of quality control and each rangehood is tested and
approved before it leaves the factory.

IMPORTANT : Please read prior to installation and operation.

Always switch the power off prior to installing, servicing or cleaning the appliance.

Remove transport tape from the lights and filters before use.

Never use the appliance without the filters.

P l e a s e r e a d t h e n o t e s o n g e n e r a l c l e a n i n g , e s p e c i a l l y t h e f i l t e r s .

Exhaust air must not be discharged into a heating flue or wall cavity, unless the

cavity is designed for that purpose.

Areas where the rangehood is installed that also have gas, oil or coal fired heaters,
must be well ventilated to prevent a partial vacuum in the room. This includes
gas hobs. (A partial vacuum in the room could result in too high a concentration
of gas in the air).