Service Manual 1

3

Disassembly

4

. POWER CORD

Refrigerating Cycle

CAUTION:

Discharge the refrigerant system using a Freon

TM

Recovery System. If there is no valve

to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon

TM

. Leave

the valve in place after servicing the system.

1. CONDENSER

Figure

27

1. Remove the control box.
2. Open the control box.
3. Disconnect the grounding screw from the control

box.

4. Disconnect the 2 receptacles.
5. Remove a screw which fastens the clip cord.

(See Figure

27

)

6. Remove the power cord.
7. Re-install the component by referring to the above

removal procedure, above.
(Use only one ground-marked hole

for ground

connection.)

8. If the supply cord of this appliance is damaged, it

must be replaced by the special cord. (The
special cord means the cord which has the same
specification marked on the supply cord attached at
the unit.)

Figure

28

1. Remove the cabinet.
2. Remove the 3 screws which fasten the

brace.

3. Remove the 3 screws which fasten the condenser

and shroud.

4. After discharging the refrigerant completely,

unbraze the interconnecting tube at the condenser
connections.

5. Remove the condenser carefully.
6. Re-install the component by referring to notes.

(See Figure

28

)

3. CAPACITOR

1. Remove the control box.
2. Remove the screw which fasten control panel from

control box.

3. Remove the screw which located in the front.
4. Open the bottom side of control box.
5. Remove the screw and the clamp which fastens

the capacitor.

6. Disconnect all the leads of capacitor terminals.
7. Re-install the components by referring to the

removal procedure, above. (See Figure

26

)

Figure