FUJITSU D1522 User Manual

Page 41

Advertising
background image

Error messages

30 - English

A26361-D1522-Z120-3-6319

Missing or invalid NVRAM token

Switch the device off and on again. If the message is still displayed, please contact your sales
outlet or customer service centre.

Monitor type does not match CMOS - RUN SETUP

Correct the entry for the monitor type in the

Main

menu of the

BIOS Setup

.

On Board PCI VGA not configured for Bus Master

In the

BIOS Setup

, in the

Advanced

menu, submenu

PCI Configuration

, set the

Shared PCI Master

Assignment

entry to

VGA

.

One or more RDRAM devices are not used
One or more RDRAM devices have bad architecture/timing
One or more RDRAM devices are disabled

Contact your system administrator or contact our customer service centre.

Operating system not found

Check the entries for the hard disk drive and the floppy disk drive in the

Main

menu and the

entries for

Boot Sequence

submenu of the

BIOS Setup

.

Parity Check 1
Parity Check 2

Switch the device off and on again. If the message is still displayed, please contact your sales
outlet or customer service centre.

Previous boot incomplete - Default configuration used

By pressing function key

[F2]

you can check and correct the settings in

BIOS Setup

. By

pressing function key

[F1]

the system starts with incomplete system configuration. If the

message is still displayed, please contact your sales outlet or customer service centre.

Real time clock error

Call the

BIOS Setup

and enter the correct time in the

Main

menu. If the message is still

displayed, please contact your sales outlet or customer service centre.

Service Processor not properly installed

The server management controller has not been correctly installed. If the message is still
displayed, please contact your sales outlet or customer service centre.

Storage Extension Group = xy
Configuration error, x Storage Extensions(s) found, configured are y
SE(s).
Device List: k1, k2 ...

The specified number of storage expansion units (SEs) in the

BIOS Setup

menu

Server - Storage

Extensions - Number of connected SE

is incorrect. Check how many SEs within the group are

connected at the server and change the setting in

BIOS Setup

. Check whether you have

assigned the same device ID twice.

xy = Group number
x = Number of SEs found on the communication bus
y = Number of SEs entered in

Number of connected SE

k1, k2 ... = Device ID of the storage extensions found

Advertising