NICD/NIMH FUNCTIONS AND PARAMETERS

Page 3

Page 1

Page 2

05]NiMH 6S 3000mAh

CHG. : 3.0A 8mV/C

DCHG. : 3.0A 0.8V/C

CYCLE : C

D 1x 10m

CUT.TEMPER. : 55°C

MAX.CAPACITY: 150%

PEAK DELAY : 3min

TRI CURRENT : 100mA

SAFETY TIMER: 120min

Cut-off Temperature

Cut-off when x% of

capacity is reached.

Do not detect peaks

for x mins.

Trickle Charge Rate

Cut-off if maximum

time is reached

Charge

Cycle

Discharge

‘CHG.’ – CHARGE

This line shows the charge current and the delta-peak cut-off voltage. These values
can be edited by pressing the ‘Enter’ button to highlight the parameter, then the ‘Inc’
and ‘Dec’ buttons to edit the value.

When charging NiCd and NiMH batteries, most chargers detect when the pack is fully
charged by using a method called delta-peak. This monitors the voltage of the pack
which increases as the pack becomes charged. When the pack is fully charged the
pack starts to get warm and the voltage then starts to drop. The delta-peak cut-off
voltage is the voltage drop (per cell) that is detected before the charger will stop the
charge. The default delta-peak voltage setting for NiMH packs is 5mV/cell and for
NiCd is 8mV/cell.

To start the charge function, press the ‘Enter’ button for 2 seconds with this line
selected. The screen will then move to the charge type screen (see page 12).

n.b. The selected charge currents will not be used if ‘Automatic’ charge type is

selected.

‘DCHG.’ - DISCHARGE

The discharge line shows the discharge current and the discharge cut-off voltage (per
cell). The default cut-off voltage for NiCd/NiMH cells is 0.8V/cell.

Pressing the ‘Enter’ button for 2 seconds with this line selected will move to the
discharge type selection screen.

n.b. The selected discharge current will not be used if ‘Automatic’ discharge type is

selected.