Pre-planning your ductwork, Dimensional diagrams, Ducted ductless – Faber 630000815 User Manual

Page 2: Pre-planning your installation, Ductless installations, Ducted, Ductless

Advertising
background image

upper

chimney

cover

ductless

lower

chimney

cover

canopy

cabinet base

x = distance from hood to cooktop

(varies depending on installation)

min - 24”, suggested max - 30”

also consult cooktop

manufacturer's recommendation

1" min
7" max

31"

36”

x

min & max ceiling height examples

x = 30"

min

8'

4 5/8"

max

8'

10 5/8"

x = 28"

min

8'

2 5/8"

max

8'

8 5/8"

x = 26"

min

8'

5/8"

max

8'

6 5/8"

x = 24"

min

7'

10 5/8"

max

8'

4 5/8"

20"

2

5/8”

3

3/4”

upper

chimney

cover

lower

chimney

cover

canopy

cabinet base

x = distance from hood to cooktop

(varies depending on installation)

min - 24”, suggested max - 30”

also consult cooktop

manufacturer's recommendation

3

3/8”

min

14

3/8”

max

23

5/8”

2

5/8”

36”

x

min & max ceiling height examples

x = 30"

min

7'

11 5/8"

max

8'

10 5/8"

x = 28"

min

7'

9 5/8"

max

8'

8 5/8"

x = 26"

min

7'

7 5/8"

max

8'

6 5/8"

x = 24"

min

7'

5 5/8"

max

8'

4 5/8"

Rev.06/08

WARNING! Product specifications are subject to change without notification. Consult the installation instructions

before you begin installing this rangehood.

Pre-Planning Your Ductwork

Ductless Installations*

For installations where ductwork is im-

possible or highly impractical, a ductless

conversion kit is available. A charcoal

filter, which attaches under the blower

assembly, absorbs smoke and odors. A

ductless diverter assembly directs the air

out to a lower chimney with a vent grate

cut into the back.

Make your ductrun as straight and short as possible. The ductrun should

not exceed 35 equivalent feet if ducted with the required minimum of 6”

round duct. Count 45º angles as 3 feet, 90º elbows as 5 feet, and 90º flat
elbows as 12 feet.

For best results, use no more than three 90° elbows. Make sure that
there is a minimum of 24” of straight duct between elbows if more
than one is used. Do not install two elbows together. If you must
elbow right away, do it as far away from the hood’s exhaust opening
as possible.

Ducted

* it is highly recommended that professional style cooking always be vented to the outside.

Ductless

Dimensional Diagrams

Pre-Planning Your Installation

-

Important: Consult the installation instructions before you begin installing this rangehood.

Note: The Ductless

Vent Grate exhausts

toward the rear of the

chimney.

Ducted

Ductless

The ducted Axia Isola chimney can be adjusted for ceilings between 7’ 5 5/ 8” and 8’ 10 5/ 8” depending on the distance between the bottom of the hood and the
cooktop (distance x in above DUCTED diagram). The ductless Axia Isola chimney can be adjusted for ceilings between 7’ 10 5/ 8” and 8’ 10 5/ 8” depending on the
distance between the bottom of the hood and the cooktop (distance x in above DUCTLESS diagram).

Advertising