En-1

ESPECIFICACIONES

ALIMENTACIÓN ........................................................................................................................................................................................................................................................ 208/230 V~60 Hz

REFRIGERACIÓN

CAPACIDAD ............................................................................................................................................................................................................................................................... 24,200 BTU/h
ENTRADA DE ALIMENTACIÓN ........................................................................................................................................................................................................................................ 2,31 kW
CORRIENTE ........................................................................................................................................................................................................................................................................... 10,1 A

CALEFACCIÓN

CAPACIDAD .............................................................................................................................................................................................................................................................. 27,600 BTU/h
ENTRADA DE ALIMENTACIÓN ........................................................................................................................................................................................................................................ 2,47 kW
CORRIENTE .......................................................................................................................................................................................................................................................................... 10,8 A

FICHE TECHNIQUE

ALIMENTATION ......................................................................................................................................................................................................................................................... 208/230 V~60 Hz

REFROIDISSEMENT

PUISSANCE FRIGORIFIQUE ..................................................................................................................................................................................................................................... 24,200 BTU/h
PUISSANCE ABSORBÉE .................................................................................................................................................................................................................................................... 2,31 kW
INTENSITÉ ............................................................................................................................................................................................................................................................................ 10,1 A

CHAUFFAGE

PUISSANCE FRIGORIFIQUE ..................................................................................................................................................................................................................................... 27,600 BTU/h
PUISSANCE ABSORBÉE ................................................................................................................................................................................................................................................... 2,47 kW
INTENSITE ............................................................................................................................................................................................................................................................................ 10,8 A

SPECIFICATIONS

POWER SUPPLY ........................................................................................................................................................................................................................................................ 208/230 V~60 Hz

COOLING

CAPACITY .................................................................................................................................................................................................................................................................. 24,200 BTU/h
INPUT POWER ................................................................................................................................................................................................................................................................... 2.31 kW
CURRENT .............................................................................................................................................................................................................................................................................. 10.1 A

HEATING

CAPACITY ................................................................................................................................................................................................................................................................. 27,600 BTU/h
INPUT POWER ................................................................................................................................................................................................................................................................... 2.47 kW
CURRENT ............................................................................................................................................................................................................................................................................. 10.8 A

MODEL

INDOOR UNIT

MODÈLE

UNIDAD INTERIOR

MODELO

UNITÉ INTÉRIEURE

OUTDOOR UNIT
UNIDAD EXTERIOR
UNITÉ EXTÉRIEURE

MW24Y3F

MR24Y3F

TYPE

HEAT & COOL MODEL

TYPE

MODÈLE RÉVERSIBLE

TIPO

MODELO DE REFRIGERACIÓN Y CAlEFACCÓN

CONTENTS

SAFETY PRECAUTIONS .................................... En-1

FEATURES AND FUNCTIONS ........................... En-2

NAME OF PARTS ................................................ En-3

PREPARATION .................................................... En-4

OPERATION ........................................................ En-5

TIMER OPERATION ............................................ En-7

SLEEP TIMER OPERATION ................................ En-8

MANUAL AUTO OPERATION ............................ En-8

ADJUSTING THE DIRECTION OF

AIR CIRCULATION .............................................. En-9

SWING OPERATION ......................................... En-10

COIL DRY OPERATION ..................................... En-10

CLEANING AND CARE ..................................... En-11

TROUBLESHOOTING ....................................... En-12

OPERATING TIPS .............................................. En-13

SAFETY PRECAUTIONS

Do not attempt to install this air conditioner by yourself.
This unit contains no user-serviceable parts. Always consult authorized service per-

sonnel for repairs.

When moving, consult authorized service personnel for disconnection and installa-

tion of the unit.

Do not become excessively chilled by staying for lengthy periods in the direct cooling

airflow.

Do not insert fingers or objects into the outlet port or intake grilles.
Do not start and stop air conditioner operation by disconnecting the power supply

cord and so on.

Take care not to damage the power supply cord.
In the event of a malfunction (burning smell, etc.), immediately stop operation, dis-

connect the power supply plug, and consult authorized service personnel.

Provide occasional ventilation during use.
Do not direct air flow at fireplaces or heating apparatus.
Do not climb on, or place objects on, the air conditioner.
Do not hang objects from the indoor unit.
Do not set flower vases or water containers on top of air conditioners.
Do not expose the air conditioner directly to water.
Do not operate the air conditioner with wet hands.
Do not pull power supply cord.
Turn off power source when not using the unit for extended periods.
Check the condition of the installation stand for damage.
Do not place animals or plants in the direct path of the air flow.
Do not drink the water drained from the air conditioner.
Do not use in applications involving the storage of foods, plants or animals, precision

equipment, or art works.

Connection valves become hot during Heating; handle with care.
Do not apply any heavy pressure to radiator fins.
Operate only with air filters installed.
Do not block or cover the intake grille and outlet port.
Ensure that any electronic equipment is at least one metre away from either the in-

door or outdoor units.

Avoid installing the air conditioner near a fireplace or other heating apparatus.
When installing the indoor and outdoor unit, take precautions to prevent access to

infants.

Do not use inflammable gases near the air conditioner.

DANGER!

CAUTION!

OPERATION

TIMER

COIL DRY

A

9

1

=

8

3

1

8

3

B C

D

5

6

4

7

E
F

H

G

Ջࣱݻବ

MANUAL

AUTO

2

Fig. 5

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 7

To facilitate explanation, the accompanying illustra-
tion has been drawn to show all possible indicators;
in actral operation, however, the display will only
show those indicators appropriate to the current op-
eration.

Fig. 6

N

Y

^

[

]

P

Q

J

K

L
I
N

W

R
S
T

U

O

V

a

b

\

Z

c

X

Advertising