Connections – Fisher VCB-3424 User Manual

Page 11

Advertising
background image

CONNECTIONS

Basic connection for monitoring or recording

The peripheral devices (VCR, monitor, lens, etc.) and cables are sold separately.

1

Make the video signal connection between the camera and the monitor or time lapse VCR.

2

Connect to 24 V AC UL listed class 2 power supply.

CAUTION:

To prevent camera and/or power supply failure, pay close attention to polarity when making the
connections.

To prevent fire hazard any UL listed wire rated VW-1, should be used for the 24 V AC cable input
terminal.

3

Insert the plug of this power cord into a wall outlet.
The POWER indicator (A) will light. Adjust the picture on the monitor using the Brightness and Contrast
controls.

Coaxial cable type and maximum length

Cable type RG-59U (3C-2V), 250 m maximum.

Cable type RG-6U (5C-2V), 500 m maximum.

Cable type RG-11U (7C-2V), 600 m maximum.

CAUTION:

The RG-59U type cable should not be run through electrical conduits or through the air.

Using CCTV/Video-grade coaxial cable.

(Video signal connections)
: VIDEO IN
: VIDEO OUT

(A)

1

2

24 V

24 V

3

L73T4/US GB 1999, 8, 3