BRAIDED HOSE TO COUPLER CONNECTION

Slip one Worm Clamp (14) onto the other end of the braided
hose (13).

Push the other end of the braided hose (13) onto the keg
coupler (11) until seated against hex head.

Secure the hose (13) to the keg coupler (11) using the
remaining worm clamp (14). Use a flat tip screwdriver to
tightly secure the worm clamp to the braided hose to prevent
gas leakage.

FIRST STEPS (continued)

COUPLER TO KEG INSTALLATION

Align locks on keg coupler (11) with housing on top of keg
and push down on the keg coupler (11).

Turn the tap head handle clockwise 1/4 turn. The tap head is
now secured to the keg.

Pull the tap handle out and push down to open the port in
the keg.

NOTE

NOTE

NOTE

NOTE

NOTE

Depending on your choice of beer, you may require
a different Keg Coupler (11). Check with your local
beer distributor to determine which type system you
need, and order additional Keg Couplers as
needed. For assistance call Electrolux Consumer

Services at 1-800-944-9044

.

CLEAR HOSE TO COUPLER CONNECTION

Place one of the supplied rubber washer (15) inside the
hex nut on the one end of the clear hose (12) (beverage
delivery line) and attach to keg coupler (11). Be sure to
tighten the nut securely to prevent leakage. DO NOT over
tighten. Over tightening may damage the gasket in the nut.

CLEAR HOSE TO DOOR PANEL CONNECTION

Place the other supplied rubber washer (15) inside the
hex nut on the other end of the clear hose (12) (beverage
delivery line) and attach to the Faucet & Shank Assembly
(6) protruding through the door panel. Be sure to tighten
the nut securely to prevent leakage. DO NOT over tighten.
Over tightening may damage the gasket in the nut.

BRAIDED HOSE TO REGULATOR CONNECTION

Slip one Worm Clamp (14) onto braided hose (13).

Attach that end of the braided hose (13) to the hose barb of
the CO

2

regulator (10). Push hose up until seated against

hex head.

Secure the braided hose (13) to the CO

2

regulator (10) using

the worm clamp (14). Use a flat tip screwdriver to tightly
secure the worm clamp.