Other iinstallation r requirements – Fagor America IFA-90 User Manual

Page 8

Advertising
background image

7

Other IInstallation R

Requirements

Your ccook-ttop m

must aalways bbreath aadequately. M

Make ssure tthat tthe aair iinlet aand iits

exhaust aare nnot oobstructed.

The uunit m

must nnot bbe iinstalled aabove aa w

washing m

machine, aa rrefrigerator oor aa ddeep-

freezer bbox

To eeliminate tthe rrisk oof bburns oor ffire bby rreaching oover hheated ssurface uunits, ccabinet
storage sspace llocated aabove tthe ssurface uunits sshould bbe aavoided.

The uunit m

must bbe iinstalled ssuch tthat iit ccan bbe ppulled w

without ddifficulty oout oof tthe ccut-oout

for sservicing oor ccleaning.

Never gglue, ssilicone oor w

wedge tthe uunit iinside iits ccut-oout.

During cooking, built-in fan inside the
cooktop will operate constantly to keep the
internal components cool. The air intake is
on the bottom of the cooktop box, and the
warm air exhaust is located on the back of
the rim, as shown on the schematic. If the air
intake or the exhaust is obstructed, the
cooktop safeties will either diminish the
power output or shut down the unit.

We suggest that you should periodically
check that there are no objects (dust, paper,

etc.) which could obstruct the air inlet under
your induction cooktop.

Although induction-cooktop heat rejection is
minimal and the unit does not create any
fumes in operation, such unit must be
installed underneath a properly sized
ventilation hood for exhausting any smell,
vapor and smoke created by cooking itself.

Also, a proper downdraft system can be
used for ventilation.

A minimum vertical clearance of 750 mm
[30”] is required between the top of the
cooking surface and the bottom of any
unprotected combustible material, such
as cabinets, wooden trim etc.

In the back, leave a minimum of 10 mm
[3/8”] between the cooktop edge and
adjacent vertical surfaces (backsplash,
wall, high cabinets etc.). This space is
needed for the unit to breath properly.

If a downdraft ventilation system is used,
a minimum of 6 mm (1/4”) of clearance
is required between the rear edge of the
cooktop and the downdraft snorkel.

Leave a minimum of 50 mm [2”]
underneath the unit for the air intake.

Air

Intake

Exhaust

Cabinet Above

Cabinet Belo

w

40 [1 5/8"

]

Minimum

Clearance

Requirements

Cross

Section

750 mm (30

”)

50 mm (2

”)

Cabinet below

Cabinet Above

750 mm 30”

10 [3/8”]