Table 1: control data ( testing with lamp off ) – Field Controls CC 2000 User Manual

Page 6

Advertising
background image

Page 6

Table 1: Control Data (testing with lamp off)

Sample

Number

Air Sampling

Duration (min)

Airflow

Velocity

fpm

Serratia marcescens

Positive hole count

Corrected Particle

Counts

CFU/FT

3

of air

(count/min)

1

1

500

181

241

2

1

500

193

263

3

1

500

208

294

4

0.5

500

117

138

5

0.5

500

118

140

Total min. = 4

Total Corrected

Particle counts

= 1076

269.00

1

2

1000

168

218

2

2

1000

167

216

3

2

1000

169

220

4

1

1000

91

103

5

1

1000

92

103

Total min. = 8

Total Corrected

Particle counts

= 860

107.50

Table 2: UV-18 Test data and results (testing with lamp on)

Sample

Number

Air

Sampling

Duration

(min)

Airflow

Velocity

(fpm)

Serratia

marcescens

Positive hole

count

Corrected

Particle

Counts

CFU/FT

3

of air

(count/min)

%Survival

CFU/Control

Log

Reduction

%

Effective

1

1

1000

30

31

2

1

1000

32

33

3

3

1000

88

99

4

6

1000

145

180

Total min = 11

Total

Corrected

Particle Counts

= 343

31.18

29.01

0.54

70.99

Control:

107.50

1

1

500

13

13

2

1

500

19

19

3

3

500

57

61

4

6

500

92

105

Total min = 11

Total

Corrected

Particle Counts

= 198

18.00

6.69

1.17

93.31

Control:

269.00