DUCTLESS

INSTALLATION DIMENSIONS

upper

chimney

cover

ductless

lower

chimney

cover

canopy

x = distance from hood to cooktop

(varies depending on installation)

min - 24”, suggested max - 30”

cabinet base

10" min

16

1/8”

max

22"

3

3/8”

36”

22"

x

also consult cooktop

manufacturer's recommendation

(not vented to the outside)

FIGURE 4B DUCTLESS INSTALLATIONS

The Diamante chimneys are adjustable and

designed to meet varying ceiling heights

as indicated in FIGURE 4B. For ductless

installations, the chimneys can be adjusted

for ceilings between 7' 11 3/8" and 8' 11 1/2"

depending on the distance between the bottom

of the hood and the cooktop (distance x).

For shorter ceilings, have the chimney cover(s)

cut at a sheet metal shop. For higher ceiling

installations, the High Ceiling Chimney Kit

includes a new 40” upper chimney which would

replace the 16 1/8” upper chimney that came

with the hood.

Note: If 24" or 30" High Backsplash is being

installed, the distance between the bottom

of the hood and the cooktop (DISTANCE X

IN FIGURE 4B) is equal to the height of the

Backsplash.

min & max ceiling height examples

x = 30"

min

8'

5 3/8"

max

8'

11 1/2"

x = 28"

min

8'

3 3/8"

max

8'

9 1/2"

x = 26"

min

8'

1 3/8"

max

8'

7 1/2"

x = 24"

min

7'

11 3/8"

max

8'

5 1/2"

38 1/8"

Advertising