Specifications

Electrical

Separate circuit and equipment ground required.

Evaporator unit

Standard electrical – 115/60/1
Maximum fuse – 15 amps
Amperage – 6 amps

Condenser unit

Standard electrical – 220V, 60Hz, 1 phase
Maximum fuse – 40 amps
Amperage – 21.4 amps

Evaporator plumbing

3/8" OD push-in water inlet

3/4" MPT
Notes: 3/4" vented drain line must slope a minimum of 1/4" per foot (6mm per 30.4cm run).

Drain to be hard piped and insulated.

Water shut-off recommended within 10 feet (3m).

Follett recommends installation of Follett water filter system (part# 00130286) in icemaker

inlet water line.

Ambient

Evaporator unit

Air temperature

100˚F/38˚C max.

50˚F/10˚C min.

Water temperature

90˚F/32˚C max.

45˚F/7˚C min.

Water pressure

70 psi max. (483 kPa)

10 psi min. (69 kPa)

Condenser unit

Air temperature

120˚F/49˚C max.

– 20˚F/-29˚C min.

Refrigeration

3/8" liquid line
5/8" suction line

Note:

Rack system installations require a reserve capacity of 10,000 BTU/hr at

0˚F (-18˚C) evaporator temperature.

Evaporator pressure regulator (not supplied) is required.

Weight

Ice

production

Evaporator unit

190 lbs (88kg)

Condenser unit

385 lbs (175kg)

F

C

50

10

60

16

70

21

80

27

90

32

60

16

1231

559

1182

537

1146

520

1110

504

1074

488

70

21

1206

548

1157

525

1121

509

1085

493

1049

476

80

27

1163

528

1127

512

1091

495

1055

479

1019

463

90

32

1128

512

1088

494

1048

476

1008

458

968

440

100

38

1098

499

1055

479

1012

460

969

440

926

421

lbs

kg

lbs

kg

lbs

kg

lbs

kg

lbs

kg

Inlet W

a

ter T

emper

atur

e F/C

Ambient Air Temperature F/C

Icemaker capacity/24 hrs.