Refrigeration system – Follett HCC1400W User Manual

Page 23

Advertising
background image

23

thermostatic

expansion

valve

compressor

High pressure vapor

High pressure liquid

Low pressure liquid

Low pressure vapor

low side

service port

high side

service port

condenser

filter dryer

high side

refrigeration

line run

low side

refrigeration

line run

Refrigeration system diagram

Air-cooled condensers (air)

50˚F/10˚C 60˚F/16˚C 70˚F/21˚C 80˚F/27˚C 90˚F/32˚C 100˚F/38˚C

Pressure (psig)
discharge/suction

190/25

217/29 241/29 276/32 317/36 358/39

Water-cooled condensers (water) 50˚F/10˚C 60˚F/16˚C 70˚F/21˚C 80˚F/27˚C 90˚F/32˚C

Pressure (psig)
discharge/suction

235/21

237/21 238/20 236/21 315/33

Note:

The water control valve is factory set to maintain 238 ± 15 psi discharge pressure @ 70˚ F water.