2 fuse replacement, 3 magnetron life, 4 lcd backlight life – Furuno FR-8252 EN User Manual

Page 111: Warning

Advertising
background image

6. MAINTENANCE & TROUBLESHOOTING

6-3

6.2

Fuse Replacement

A fuse is in the fuse holder on the power cable and inside the power supply unit, and they protect
the equipment from reverse polarity of the ship's mains and equipment fault. If a fuse blows, find
out the cause before replacing it. Use the correct fuse. Using the wrong fuse will damage the
equipment and void the warranty.

6.3

Magnetron Life

When the magnetron (generates microwaves) has expired, distant targets cannot be seen on the
display. When you feel that long range performance has decreased, contact a FURUNO agent or
dealer about replacement of the magnetron.

6.4

LCD Backlight Life

The life of the LCD backlight, which provides illumination for the LCD, is approximately 4,300
hours. The display brilliance cannot be raised when the backlight has worn out. Have a qualified
technician replace the backlight when brilliance cannot be raised.

Unit and fuses

Unit

Type

Code No.

Remarks

DIsplay unit
(fitted on power
cable)

FGBO 15A AC125V

000-549-014

12 VDC

FGBO 10A AC125V

000-549-065

24 VDC

Power supply unit
(for FR-8252)

FGBO 15A AC125V

000-549-014

12 VDC

FGBO 7A AC125V

000-549-013

24 VDC

Model and magnetron

Model

Magnetron type

Code no.

Estimated life

FR-8062

MAF1422B

000-146-871

Approx. 3,000 hours

000-158-788-10

MG4006

000-150-838

FR-8122

MAF1425B

000-158-790-10

FR-8252

M1458F

000-158-780-10 Approx 1,000 hours

Part

Type No.

Code No.

Lamp holder complete set

121LHS18

000-158-827-10

WARNING

Use the proper fuse.

Use of a wrong fuse can result in damage
to the equipment or cause fire.

Advertising