READ AND SAVE THESE INSTRUCTIONS.

FUJI INDUSTRIAL CO.,LTD .

Keep this manual in a convenient place for future reference.

www.fujioh.com

INSTALLATION MANUAL

WS06

FIG 2

1.

2.

3.

4.

030984

WARNING

IMPORTANT

Connect the electrical wires in accordance with

wiring diagram (figure 1).

Connect wires tightly and securely using wire

connectors (not supplied).

Turn on the electrical circuit to the power unit. Check

the ventilating functions at each speed control

positions. Make sure that the range hood has no

abnormal noises and/or vibration.

Your installation is now complete.

If you should require service or replacement

parts on your ventilation system.

contact:

Fuji Industrial USA,Inc.

16300 Christensen Rd, #212 Seattle, WA 98188

1-888-547-9880

A 2-1/2" deep Wall Box must be used to allow space for

wire connections between switch and 120 volt Power

Input Leads.

Attach the wall plate, and secure with 2 screws.

Electrical wiring should be done by a qualified person(s)

in accordance with all applicable codes and standards,

including fire-rated construction. An unqualified person

doing the work could result in fire, electric shock or injury.
This switch uses 120 V AC, Max 16 Amp. Do not connect

to other voltage or over current rate since fire, electric

shock or damage could result.

Be sure to switch power OFF at service panel before

wiring.

2-1/2" Deep Wall Box

(

must be grounded)

Bowers #52 or Equivalent

Motor Green or

Bare Ground Wire

- Grounded to

Wall Box

From
Blower Moter

< CONNECTING POWER SUPPLY WIRES >

FIG 1 < Connection Diagram >

Top

HI

OFF

LO

MED

Black

Ground

Neutral

Red

Blue

No Use

Switch:Red

Motor:Red

Low

Motor:Blue

Medium

Power Supply: White

M

GREEN/ GROUND

WHITE
/NEUTRAL

BLACK
/120V AC

GE Switch:
ASR-4173-500
(UL Recognized
Component)

Switch:Blue

Switch:Yellow

Power Supply Black

Switch:Black

Motor Black

High

Motor:White

Switch: Blue

Medium speed

Switch: Red

Low speed

Switch: Yellow

Switch: Black

High speed

Must use this wiring diagram for installation.

Do not use Thermador wiring diagram.