95% AFUE, ALL-POSITION, TWO-STAGE, VARIABLE SPEED GAS FURNACE

Model Number

FV95A0543A

FV95A0723A

FV95A0905A

FV95A1085A

Position

All-Position

All-Position

All-Position

All-Position

Electrical Characteristics

Volts

120

120

120

120

Hertz

60

60

60

60

Phase

1

1

1

1

Operating Voltage Range (Min-Max)

102 - 132

102 - 132

102 - 132

102 - 132

Max Fuse or CKT Breakers (Amps)

15

15

15

15

Minimum Wire Size

14

14

14

14

Performance Data - Input BTUH

Low

35,100

46,800

58,500

70,200

High

54,000

72,000

90,000

108,000

Performance - Cooling Data

Furnace Cooling Category (Tons)

1.5 - 3

1.5 - 3.5

2.5 - 5

2.5 - 5

AFUE%

Direct Vent (2 pipe)

Upflow

95

95

95

95

Direct Vent (2 pipe)

Horizontal / Downflow

94

94

94

94

Min. Output Capacity

Direct Vent (2 pipe) - Low

Upflow

33,345

44,460

55,575

66,690

Direct Vent (2 pipe) - Low

Horizontal / Downflow

32,994

43,992

54,990

65,988

Direct Vent (2 pipe) - High

Upflow

51,300

68,400

85,500

102,600

Direct Vent (2 pipe) - High

Horizontal / Downflow

50,760

67,680

84,600

101,520

Certified Temperature Rise

Temperature Rise (°F )

Low

35 - 65

35 - 65

35 - 65

35 - 65

Temperature Rise (°F )

High

35 - 65

35 - 65

35 - 65

35 - 65

Airflow at 0.5" Static

Airflow CFM Approx

Low Heating ∆T 50°F

618

823

1,029

1,235

Airflow CFM Approx

High Heating ∆T 50°F

950

1,267

1,583

1,900

Airflow

Cooling Max

1,200

1,400

1,800

1,900

Component Data

Blower Information

Blower Diameter & Width (Inches)

11 x 7

11 x 7

11 x 10

11 x 10

Variable Speed Motor

3/4 hp - ECM

3/4 hp - ECM

1 hp - ECM

3/4 hp - ECM

Motor Speed

Variable

Variable

Variable

Variable

Motor Full Load Amps

7.7

9.6

12.8

9.6

Inducer Draft Blower

Type

2-Speed

2-Speed

2-Speed

2-Speed

Product Specifications

2

Specifications subject to change without notice.