3) electrical data (continued), Electrical requirements, Electrical rating tables – Friedrich A-SERIES User Manual

Page 8

Advertising
background image

8

920-075-08

Electrical Requirements

Figure 6

3) Electrical Data (continued)

Electrical Rating Tables

NOTE: Use copper conductors ONLY. Wire sizes are per

NEC. Check local codes for over seas ap pli ca tions

Recommended branch circuit wire sizes*

Nameplate

maximum circuit

breaker size

AWG Wire size**

15A

14

20A

12

30A

10

AWG — American Wire Gauge
* Single circuit from main box
** Based on copper wire, single in su lat ed conductor at 60°C

Note: All fi eld wiring must comply with NEC and local codes. It
is the responsibility of the installer to insure that the electrical
codes are met.

Wire Size

Use ONLY wiring size recommended for single
out let branch circuit.

Fuse/Circuit
Breaker

Use ONLY type and size fuse or HACR circuit
breaker indicated on unit's rating plate (See sample
on page 6). Proper current protection to the unit is
the responsibility of the own er.

Grounding

Unit MUST be grounded from branch circuit to
unit, or through separate ground wire provided on
permanently connected units. Be sure that branch
circuit or general purpose outlet is ground ed.

Wire Sizing

Use recommended wire size given in tables and
install a single branch circuit. All wiring must comply
with local and national codes. NOTE: Use copper
conductors only.

CAUTION

Elec tric shock haz ard.

Turn OFF elec

tric pow er be fore service

or in stal la tion.

All electrical connections and wir ing MUST
be in stalled by a qual i fi ed elec tri cian and
con form to the Na tion al Elec tri cal Code and
all local codes which have ju ris dic tion.

Failure to do so can result in prop er ty
damage, per son al injury and/or death.

Advertising