First Alert MODEL FCD3N User Manual

Page 10

Advertising
background image

9

For Tabletop Use

1. Close the battery

compartment by
sliding the mounting
bracket/battery door
back onto the back of
the CO Alarm.

2. Test the CO Alarm as described below.

3. Set the CO Alarm in plain view on a table

where it will not be blocked by any
obstructions.Table height should not exceed
36” (92 cm).

IMPORTANT!

Put the CO Alarm where children and pets
cannot reach it.

To Mount On The Wall

Tools you will need: pencil, drill with 3/16” or
5mm drill bit, flathead screwdriver, hammer.

1. Choose a location on the wall. Do not install

the alarm closer than 4” from where the wall
meets the ceiling.

2. Hold the mounting bracket

against the wall, and make
a mark inside each
keyhole where you will drill
your mounting hole.

3. Use a 3/16” drill bit to drill

through the marks you made for the
mounting holes.

4. Insert the plastic screw anchors into the

mounting holes until they are flush with the
wall. If necessary, tap them gently with a
hammer.

5. Line up the mounting

bracket up with the
screw anchors, and
screw the bracket onto
the wall.

6. Slide the CO Alarm

onto the mounting bracket until you feel it
click into place.

7. Test the CO Alarm as described in “To Test

this CO Alarm.”

To Test this CO Alarm:

Push and hold the Test/Silence button on the
cover until you hear a “chirp.” The “chirp” marks
the start of the self-test sequence.

First, the yellow and green lights will
flash briefly—this is normal.

Next, the alarm horn will sound: 4 beeps,
a pause, then 4 beeps. The red light will
flash quickly.

The alarm sequence should last 5-6 seconds.
If it does not alarm, make sure the battery is
correctly installed, and test it again. If the unit still
does not alarm, replace it immediately.