23

Problem

Possible Causes

What To Do

Salty tasting or

Unit not sanitized

• Complete the Sanitization Procedures on page 13.

brown/yellow colored

• At completion of recharge cycle (approx. 2 hrs), run water

water after installation

from faucets to purge the salty water.

Low water pressure

Check pressure.
• Drain height 8

′ or less, pressure should be minimum of 20 psi.

• Drain height above 8

′, pressure should be minimum of 50 psi.

Restricted drain hose

• Clean and reconnect hose.

• Check for kinks in drain line.

Brown/yellow

Unit was idle for a period of time

• Complete the Sanitization Procedures on page 13.

colored water

Resin beads showing

Cracked distributor

• Call for service.

up in drinking water
and sink

Sounds you might hear

Running water from the unit

• This is normal.

into a drain during recharge

Water has air bubbles

Air in system after installation

• Will go away after it runs for a while.

and is cloudy

Error Code on control

Wiring may have worked loose

• See page 17 for details.

in the control

• Unplug transformer.

• Remove control cover, release clips on side.

• Check for loose/incorrect wiring connections to electronic

board or switch. Reconnect as required.

• Reassemble control cover.

• Plug in Transformer.

• Wait six minutes for Error Code to reappear.

• If Error Code reappears, call for service.

ge.com

Blue light flashing

When power applied

Control needs to be programmed

• See the Programming the Control section, page 10.

to the system

(a power outage may have occurred)

If “DAYS TO EMPTY”

Low salt level, less than 15 days

• Fill with salt.

is flashing

• Reset salt level.

If “Err” in display

Electrical problem with system

• See page 17 for details.

• See procedure above, Error code on control.