20

SERVICING INSTRUCTIONS

REPLACING PARTS

7.3 Reassemble the interrupter block and leads. Secure the

thermocouple connection in the rear of the gas control (Do

not overtighten). Turn the gas supply on and check the

entire pipework and valve joints for any leaks.

8. MAIN INJECTOR

8.1 Turn the gas supply off at the isolation device. Refer to

Section 2, Replacing Parts to remove the main burner.

8.2 Undo the compression nut from the feed pipe at the gas

control under the appliance.

8.3 Working from inside the firebox, remove the lock nut from

the injector, see diagram 15 and withdraw the injector

complete with the feed pipe from under the appliance. See

diagram 15.

8.4 Holding the injector with a spanner, undo the feed pipe.

NOTE: THE ORIENTATION OF THE INJECTOR.

8.5 Reassemble in reverse order. Turn on the gas supply and

check for any leaks.

9. GAZCO FLUE SURE SYSTEM

9.1 Remove the front door by undoing the four dome nuts and

remove the cast iron door. NOTE: THE CAST IRON DOOR

IS HEAVY. TAKE EXTREME CARE WHEN HANDLING.

Carefully remove the coal retainer and ceramic components

and place to one side. Remove the burner casting by

removing the three screws located on the sides of the burner

skin.

9.2 Remove the screw on the back panel and remove the panel.

Refer to Diagram 17.

9.3 Undo the two screws at the back of the firebox and carefully

withdraw the bracket.

9.4 Disconnect the two slender wires. Undo the two taptite

screws and remove the sensor and the two plastic spacers.

See diagram 19.

AR1607

18

AR1446

19

AR0618

15

AR1605

16

AR1606

17

Advertising