Gravely 927064-1440 User Manual

Page 19

Advertising
background image

GB - 19

Cleaning Battery and Battery Cables
(Figure 20)

1. Remove battery from unit (see Battery

Removal and Installation on page 18).

2. Clean or service battery away from unit.

Remove corrosion from battery terminals
and cable connections with wire brush,
then wash with a weak baking soda
solution.

3. Install battery on unit (see Battery

Removal and Installation on page 18).

Charging the Battery
(Figure 20)

Follow First Aid directions for contact with
battery fluid.

• External Contact: Flush with water.

• Eyes: Flush with water for at least 15

minutes and get medical attention
immediately!

• Internal Contact: Drink large quantities of

water. Follow with Milk of Magnesia,
beaten egg or vegetable oil. Get medical
attention immediately!

• In case of internal contact, DO NOT

induce vomiting!

IMPORTANT: DO NOT fast charge.
Charging at a higher rate will damage or
destroy battery.
IMPORTANT: ALWAYS follow information
provided on battery and battery charger.
Contact battery and battery charger
manufacturers’ for detailed instructions.

1. Remove battery from unit (see Battery

Removal and Installation on page 18).

2. Place battery on bench or other well-

ventilated area.

3. Connect positive (+) lead of charger to

positive (+) terminal, and negative (–)
lead of charger to negative (–) terminal.

4. Charge battery according to battery

charger and battery manufacturers’
instructions.

OE0028

4

11

3

10

6

9

8

5

1

2

7

Figure 20

1. Seat

2. Detent Pin

3. Operator Presence

Switch Wires

4. Seat Retainer Slot

5. Battery Hold Down

Bracket

6. Battery

7. Cross Brace
8. Negative (–) Terminal

9. Negative (–) Cable

10.Positive (+) Cable

11.Positive (+) Terminal

WARNING: FROZEN BATTERIES
CAN EXPLODE
and result in death
or serious injury. DO NOT charge a
frozen battery. Let the battery thaw
before charging.

Advertising