Troubleshooting – Global Machinery Company GEN1000 User Manual

Page 18

Advertising
background image

18

Troubleshooting

Trouble

Possible cause

Suggested remedy

Engine will not start

1. Low on fuel or oil content

1. Add fuel or oil

2. Ignition switch in “Off” position

2. Turn the ignition to the ‘START’ position

if using key start, or ‘ON’ position if

manually starting.

3. Faulty spark plug

3. Replace spark plug

4. Choke in wrong position

4. Adjust choke accordingly

5. Fuel shut-off valve in closed position

5. Open fuel shut-off valve

6. Unit loaded during start-up

6. Remove load from unit

7. Spark plug wire loose

7. Attach wire to spark plug

8. Fuel filter (tap extension filter) blocked

8. Check by removing fuel line from

carburetor and opening tap. If no flow,

and tap is on, and fuel in tank there is

a blockage.

Remove tap and clean filter.

No electrical output

1. Faulty receptacle

1. Have service centre replace receptacle

2. Circuit breaker kicked out

2. Depress and reset

3. Worn Brushes

3. Have service centre replace brushes

4. Faulty power cord

4. Replace cord

Repeated circuit breaker

tripping

1. Overload

1. Reduce load

2. Faulty cords or equipment

2. Check for damaged, bare, or frayed

wires on equipment. Replace.

3. D.C Tripping

3. Remove or reduce any 240V appliances

Generator overheating

1. Generator overloaded

1. Reduce load

2. Insufficient ventilation

2. Move to adequate supply of fresh air