2 subscriber level configuration parameters, Subscriber level configuration parameters – Grandstream Networks Grandstream GXP-2000 User Manual

Page 14

Advertising
background image

BROADSOFT PARTNER CONFIGURATION GUIDE - GRANDSTREAM GXV-3000 / GXP-2000

DOCUMENT NUMBER

©

2006 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.

PAGE 14 OF 25

6.2 Subscriber Level Configuration Parameters

This section identifies the device-specific parameters, including registration and
authentication. These settings must be unique across devices in order to be matched with
the settings for a BroadWorks subscriber.

Provisioning a subscriber to register with BroadWorks allows calls to terminate to the
subscriber’s line. Registration requires that a unique address of record (AoR) is
provisioned on BroadWorks and the phone; provisioning an AoR on BroadWorks consists
of setting the line/port parameter to a unique value within the Application Server cluster.

Grandstream GXV-3000 / GXP-2000 / BT-200 supports three SIP accounts (lines), four
SIP accounts, and 1 SIP account respectively. The follow example shows how to
configure subscriber elements for an account.

Step

Command

Purpose

Subscriber Configuration Items

Step 1

Enable a line to be used.

Account Active = "Yes" ;

Enable a line of GXV-3000 / GXP-
2000 / BT-200 in use.

Step 2

Set Register User ID for a line.

Example:

SIP User_ID = "2405551111" ;

The register user ID must
correspond with the line/port
setting on BroadWorks.

Step 3

Enable SIP Authentication for a
line.

Example:

Authenticate ID =

"[email protected]" ;
Authenticate Password = "welcome"
;

If the Authentication service is
configured on BroadWorks, these
parameters must be configured to
match the BroadWorks settings.

Step 4

Configure display name for a
line.

Example:

Name = “Claire Smith” ;

For a line, configure the name to
be displayed on the device.

Advertising