Air filter

WARNING.

The air filter must be added before first use.

Failure to fit the air filter will

damage the compressor and will

void the warranty.
1. To fit the air filter (15) you

need to locate the inlet

hole on the right side of the

compressor housing then

carefully hand tighten the

thread of the the air filter in

a clockwise direction until tight.

Maintaining the air filter

1. To clean the air filter insert you need to take the air filter

(15) apart first. Undo the wing nut, and remove the cover

along with the washer from the air filter.

2. Push out the air filter insert and soak it in warm soapy

water, rinse and wring dry.

3. Replace the air filter insert cartridge, then the air filter

cover, washer, then wing nut.

Pre-start routine

1. Ensure that the location for the compressor is clean,

dry and well ventilated.

2. Ensure the crank case has been filled with oil and is

at the correct level, and the air filter has been fitted.

3. Open the regulated output

valve (6). Open the valve by

rotating the air tap (18) so it is

in line with the air outlet (refer

to the OPEN picture).

To close the valve, rotate the

air tap so it is facing to the

right or the left side of the air

valve (refer to the CLOSED

picture).

4. Start the compressor by

following the procedure in

the section “To start and stop

the compressor”. For the first

time of operation, run the

compressor for 10 minutes

with no load and with the

outlet valve open to ensure all

parts are well lubricated.

WARNING.

Be aware that pressurised air will be discharged

from the outlet and care should be taken that this discharge

is not directed towards you the operator, or other persons

within the area.

To start & stop the compressor

1. Check the rating label on the compressor indicates

230V–240V.

2. Plug in the mains cable of the compressor to a standard

240V household power point and turn on.

3. To start the compressor, lift the On/Off switch (3) on the

pressure switch cover (2).

4. To stop the compressor, push the On/Off switch down.