Graco Inc. Hydra-Clean 308-507 User Manual
Page 15

308–507
15
TECHNICAL DATA
5:1 MONARK
(Cart Mounted)
10:1 PRESIDENT
(Cart Mounted)
10:1 PRESIDENT
(Tank Mounted)
Air Pressure
40 to 180 psi (3 to 12 bar)
40 to 180 psi (3 to 12 bar)
40 to 180 psi (3 to 12 bar)
Maximum Air Pressure To
Regulator
300 psi (21 bar)
300 psi (21 bar)
300 psi (21 bar)
Maximum Pump Air Pressure 180 psi (12 bar)
180 psi (12 bar)
180 psi (12 bar)
Maximum Working Pressure
900 psi (62 bar)
1800 psi (124 bar)
1800 psi (124 bar)
Maximum Flow Rate
(Continuous Duty)
2.5 gpm (10 lpm)
3.0 gpm (11 lpm)
3.0 gpm (11 lpm)
Pump Cycles/Displacement
28 cycles/gallon
(8.0 cycles/liter)
20 cycles/gallon
(5.3 cycles/liter)
20 cycles/gallon
(5.3 cycles/liter)
Maximum Air Consumption
25 cfm (94 lpm)
40 cfm (151 lpm)
40 cfm (151 lpm)
Unit Weight
97 lbs (44 kg)
108 lbs (49 kg)
172 lbs (78 kg)
Overall Dimensions
Length
Width
Height
29 in. (737 mm)
27 in. (686 mm)
46 in. (1168 mm)
29 in. (737 mm)
27 in. (686 mm)
46 in. (1168 mm)
36 in. (914 mm
25 in. (635 mm)
43 in. (1092 mm)
Maximum Inlet Water
Temperature
200_ F (93_ C)
200_ F (93_ C)
200_ F (93_ C)
Inlet Hose Connection
3/4 in. garden hose (f)
3/4 in. garden hose (f)
3/4 in. garden hose (f)
Wetted Parts
High Pressure Hose
Pressure Washer
(including fittings)
Acrylonitrile and Buna–N cover and tube
Anodized aluminum, Aluminum or bronze alloys, Brass Copper, Nylon–
r
composite,
Viton
r
, Buna–N, Cotton phenolic, 303, 304, and 316 Stainless steel, Polymide–12
thermoplastic,
r
, Carbon steel, Zinc with or without yellow chromate plate
and V
iton
r
are tradenames of the DuPont Company
.
ACCESSORIES
(Must be purchased separately)
Air Line Filter
106-149
(1/2 npt inlet and outlet)
250 psi (17 bar) maximum working pressure.
Air Line Lubricator
214-848
(1/2 npt inlet and outlet)
250 psi (17 bar) maximum working pressure.
Bleed Type Master Valve (Required)
107-142
(1/2 npt inlet and outlet)
300 psi (21 bar) maximum working pressure.
Pump Runaway Valve
215-362
(3/4 npt inlet and outlet)
180 psi (12 bar) maximum working pressure. Shuts off air
to the pump automatically if it senses that the pump is
running too fast, a condition caused by a depleted water
supply.
Grounding Wire
208-950
25 ft. (7.6 m) 12 ga wire
Grounding Clamp
103-538
Backflow Preventer
801-133
Prevents the backup of contaminated water into the fresh
supply. Installs upstream of the pump.
Inlet Pressure Regulator
800-258
Regulates inlet water pressure to 60 psi (4 bar)
maximum.
Wall Mount Bracket
206-220
Foamer
207-640
TSL–Throat Seal Liquid
Non evaporating solvent for wet cup
206–995 1 Quart (.9 Liter)
206–996 1 Gallon (3.8 Liter)
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE