2.2.5 COMPARTMENT FLOOR CUTOUTS

‹

Provide openings in the generator compartment for the following

items (Figure 2.8):

Engine exhaust and cooling air outlets

Generator cooling air inlet

Four holes for passage of generator mounting bolts. See the

"Generator Restraint" section.

DANGER

Fuel lines and exhaust piping must not penetrate

into the vehicle living area.

2.3 COOLING AND VENTILATING

AIR

It is absolutely essential that an adequate flow of air for cooling,

ventilating and engine combustion be supplied to the generator set.

Without sufficient airflow, the engine/generator quickly overheats.

Such overheating can cause serious operating difficulties and also

may cause fire and personal injury. The installer must make sure

that sufficient air is available to the generator for cooling, ventilat-

ing and combustion. The installer also must provide for a path for

exhausting the cooling air to the exterior of a compartment, if so

equipped.

Section 2 – Installation

Recreational Vehicle Generator

Figure 2.8 – Compartment Floor Cutout