Prison Mode operation

(class iV aPPlicatioNs)

Prison mode operation means that constant pressure at the

CLOSE

or the

OPEN

push button station

input is required to move the gate in the desired direction.

Follow these steps to toggle the PRISON MODE operation on/off:

1.

Power down the unit.

2.

Press and hold the

OPEN

and

CLOSE

push button while powering on the unit.

3.

The

PRISON MODE LED

indicator will be on if operating in prison mode.

4.

Repeat the above steps to turn off prison mode operation.

Press and hold at power up to toggle

to prison mode.

COM

COM

CYCLE

SAFETY

SHADOW

OPEN

CLOSE

STOP

OPEN

EDGE
CLOSE

EDGE

LIMIT ADJUSTMENTS

TEST SWITCHES

CLOSE

STOP

OPEN

GTO Inc. Tallahassee, FL

SX4000 Logic Board Rev. E

MIN

MAX

MIN

MAX

OFF

120

<<< JOG >>>

<<< >>>

SET

LIMIT

W1

CUT TO USE

3 BUTTON

STATION

C

O

M
C

O

M

AUTO CLOSE

TIMER

OPEN

CLOSE

OPEN

CLOSE

OPEN

CLOSE

STOP

W1

CUT TO USE

3 BUTTON

STATION

Wiring a 3-button station

CYCLE

SAFETY

OPEN EDGE

CLOSE EDGE

OPEN

CLOSE

STOP

COM

COM

COM

SHADOW

LOOP

OPEN

CLOSE

STOP

NOTE: The W1 Jumper must be cut in order

to use a 3-button station.

To restore normal operation of cut jumper

you must connect a wire between the

STOP

and

COM

terminals (or you could use

a normally closed push-button). This wire

functions the same as the W1 jumper.

COM

COM

COM

CYCLE

SAFETY

SHADOW

OPEN

CLOSE

STOP

OPEN

EDGE
CLOSE

EDGE

W1

CUT TO USE

3 BUTTON

STATION

Advertising