Cleanup – Graco Inc. 1095 Premium Hi User Manual

Page 16

Advertising
background image

Cleanup

16

3A0156A

Cleanup

1.

Perform Pressure Relief Procedure (page 8),
steps 1 - 4. Remove siphon tube set from paint and
place in flushing fluid. Remove tip guard from gun.

NOTE: Use water for water-base paint, mineral spirits
for oil-base paint, or other solvents recommended by
manufacturer.

2.

Turn power ON. Turn prime valve forward to SPRAY
position.

3.

Increase pressure to 1/2. Hold gun against paint
pail. Take trigger safety OFF. Trigger gun until flush-
ing fluid appears.

4.

Move gun to waste pail, hold gun against pail, trig-
ger gun to thoroughly flush system. Release trigger
and put trigger safety ON.

5.

Turn prime valve down to DRAIN position and allow
flushing fluid to circulate until flushing fluid appears
clear.

6.

Turn prime valve forward to SPRAY position. Trigger
gun into flushing pail to purge fluid from hose.

7.

Raise siphon tube above flushing fluid and run
sprayer for 15 to 30 seconds to drain fluid. Turn
power OFF

8.

Turn prime valve down DRAIN position. Unplug
sprayer.

ti2756a