REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION

• Your dryer is approved for installation in

an alcove or closet, as stated on a label on
the dryer back.

• The dryer MUST be vented to the outdoors. See

the EXHAUSTING THE DRYER section.

• Minimum clearance between dryer cabinet and

adjacent walls or other surfaces is:

0

″ either side

3

″ front and rear

• Minimum vertical space from floor to overhead

shelves, cabinets, ceilings, etc., is 52

″.

• Closet doors must be louvered or otherwise

ventilated and have at least 60 square inches
of open area equally distributed. If the closet
contains both a washer and a dryer, doors must
contain a minimum of 120 square inches of open
area equally distributed.

• The closet should be vented to the outdoors

to prevent gas pocketing in case of gas in the
supply line.

• No other fuel-burning appliance shall be

installed in the same closet with the dryer
(gas models only).

NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT
THE REAR OF THE DRYER, MINIMUM CLEARANCE
FROM THE WALL IS 5.5 INCHES.

BATHROOM OR BEDROOM
INSTALLATION

• The dryer MUST be vented to the outdoors. See

EXHAUSTING THE DRYER.

• The installation must conform with local codes or,

in the absence of local codes, with the NATIONAL
ELECTRICAL CODE, ANSI/NFPA NO. 70 (for electric
dryers) or NATIONAL FUEL GAS CODE, ANSI Z223
(for gas dryers).

MOBILE OR MANUFACTURED HOME
INSTALLATION

• The installation must conform to the

MANUFACTURED HOME CONSTRUCTION & SAFETY
STANDARD, TITLE 24, PART 32–80 or, when such
standard is not applicable, with AMERICAN
NATIONAL STANDARD FOR MOBILE HOME,
NO. 501B.

• The dryer MUST be vented to the outdoors with

the termination securely fastened to the mobile
home structure. (See EXHAUSTING THE DRYER.)

• The vent MUST NOT be terminated beneath a

mobile or manufactured home.

• The vent duct material MUST BE METAL.

• FOR GAS MODELS ONLY: KIT 14-D346-33 MUST be

used to attach the dryer securely to the structure.

• FOR GAS MODELS ONLY: The vent MUST NOT be

connected to any other duct, vent or chimney.

• Do not use sheet metal screws or other

refastening devices which extend into the interior
of the exhaust vent.

• Provide an opening with a free area of at least

25 sq. in. for introduction of outside air into the
dryer room.