In case of difficulty

Care of your Clearview Cordless Caller Display

The Caller Display should be cleaned with a soft dry cloth. It is important to unplug the

main base unit from the mains supply and telephone socket prior to cleaning. Do not

apply polishes or strong cleaning agents as these could damage the moulding.
THUNDERSTORMS: During thunderstorms, lightning may strike telephone lines, this

can damage any equipment attached to a line, including telephones and telephone

equipment. If possible, unplug your telephone or telephone equipment from the socket in

the event of a storm.

Conditions of use

Your Geemarc Clearview Cordless Caller Display has been approved for use on

private direct exchange lines and business lines. It is also approved for use with

approved compatible PABX’s.
Your exchange line should be a standard exclusive (DEL) and not a shared service or

party line.
Your line should be Multi Frequency (TONE) dialling. If you experience any difficulty

contact your network service provider.

Approval

This product complies with the requirements of EC directive 89/336EEC. Any modification

of the unit or connection to non approved accessories may affect this compliance.

Guarantee

From the moment your Geemarc product is purchased, GeemarcTelecom Ltd guarantee

it for one year. During this time, all repairs or replacements at our option are free of

charge. Carriage to Geemarc is payable by the sender.
The guarantee does not cover accidents, negligence or breakages to any parts. The unit

parts must not be tampered with or taken apart by anyone who is not an authorised

Geemarc representative.
The guarantee of Geemarc Telecom Ltd in no way limits your legal rights.
Should you experience a problem then contact our helpline or the retailer from whom you

purchased your Geemarc product.
If you do have to return the product to Geemarc Telecom Ltd, please enclose a note of

your name and address with details of the problem being experienced. Also, enclose a

copy of your purchase receipt and a cheque for £5 to cover return postage and packing.

YOUR RECEIPT IS YOUR GUARANTEE
Please note: The guarantee applies to the United Kingdom only.
Geemarc reserve the right to modify the design and specification of the product and

related equipment in line with our policy of continuous product improvement.

Geemarc Telecom Ltd

5 Swallow Court

Swallowfields

Welwyn Garden City

Hertfordshire AL7 1SB

Helpline - 01707 384438 Facsimile - 01707 372529

Setting options for Clearview Cordless Caller Display

You may select the LCD contrast level (factory setting as level 2); the call alert tone

either On or Off (factory setting is Off); the clock either 12 or 24 hour format (factory

setting is 24 hour); and the alarm clock either On or Off (factory setting is Off).
1. Press Set for 5 seconds, until you see “--OPTIONS--”.

2. Press Review Forward repeatedly to scroll through current option settings.

3. Any time you wish to change a setting, press Set.

4. The last section in this option mode is name setting. If you want to exit from the

option mode, simply press Review Forward. Press Set to enter name setting for

phone directory (see section below).

Alarm clock setting

1. Press Timer for 5 seconds, until you see “ALARM ON or OFF”.

2. Press Set to toggle the On/Off setting.

3. When Alarm On, press Review Forward or Backward to show the current alarm

time setting and press Set if you want to change it.

4. Use Review Forward or Backward to scroll the hour and Learn to advance to

minute.

5. When the alarm time setting is OK, press Set to finish setting and you will hear a

confirmation beep.

Note - When the alarm has been set to On, a “*” symbol appears at the bottom right

corner of the display. When the alarm is activated it will beep for 1 minute. Press any

key to stop the alarm.
The alarm will operate at the same time the next day unless it is set to off. See setting

options above.

Name setting for Phonebook Directory for name mapping (50 entries)

1. At the last part of the option mode, the display shows “NAME SETTING”. Press

Set.

2. Press Review Forward or Backward to scroll to the record that you want to input.

3. Press Set to select the record. The display will show the record number and “0”

in the telephone number field.

4. Use Review Forward or Backward to select the digit. Learn to advance to next

digit. Delete for correction.

5. When all digits are OK, press Set to jump to the name field.

6. Press Review Forward or Backward to select the character. Press Learn to

advance to next character.

7. When all characters in the name are OK, press Set to finish this record setting and

you will hear the confirmation beep. The display will advance to the next record.

8. Press Timer to quit the name setting mode.
Note - Phonebook directory entries cannot be deleted but can be changed by editing

them.

Editing a phonebook directory entry

1. At the last part of the option mode, the display shows “NAME SETTING”. Press

Set.

2. Press Review Forward or Backward to scroll to the record that you want to

change.

3. Press Set to select the record.

4. Press Delete until number is erased.

5. Use Review Forward or Backwards to select the digit. Learn to advance to next

digit.

6. When all digits are OK, press Set to jump to name field.

7. Press Delete until name is erased.

8. Use Review Forward or Backwards to select the character. Learn to advance

to next character.

9. When all characters are OK press Set to select next entry to be edited by using

Review Forward or Backward.

10. Press Timer to quit editing.

What to do if “CHECK BASE” is seen on Clearview display

This means that the base is disconnected, or the ID code was not set properly, or the

Clearview display is out of range. Check base is connected to telephone modular

socket, verify ID code, or move the Clearview display closer to the base and press

Page to confirm in range.

How to change the base identification code?

Your base comes with a random identification generated at the factory. Should you want

to change it, press Set then Page and keep both keys depressed for 5 seconds until the

new random code is shown. Remember you must then set your Clearview display to

this new code.