24” unitized spacemaker, Washer/dryer – GE Unitized Spacemaker WSM2420DCC User Manual

Page 2

Advertising
background image

GE Appliances

For complete information, see installation instructions packed with your dryer.
Ducting Materials:

This dryer MUST be vented with 4" diameter all rigid metal exhaust duct.
Exhaust Length Calculation:

1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated

as a 90° elbow.
Dryers must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the

accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with

a kitchen exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at

least 12" above the ground or any other obstruction with the opening pointed down.

Special Installation Requirements
Alcove or Closet Installation:

• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.

• The dryer MUST be exhausted to the outside.

• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:

0" either side

3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".

• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed.

If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.

• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:

• The dryer MUST be exhausted to the outdoors.

• The installation must conform with the local codes, or in the absence of local codes, with the National Electric Code and National Fuel Gas

Code, ANSI Z223 for gas dryers.

Minimum Clearances other than Alcove or Closet Installation:

• Minimum clearances to combustible surfaces

0" both sides

3" rear

Listed by

Underwriters

Laboratories

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

GEAppliances.com or call

GE Answer Center

®

service, 800.626.2000.

Specification Revised 5/09

360327

Best performance

Domestic

dryer models

Maximum length of 4"

dia.

rigid metal duct

Number

of

90°

turns

Exhaust hood type

A

4"

opening

B

2-1/2"

opening

DSKS433EB

DSKS333EC

DSKP333EC

WSM2780H

0

1

2

3

46 ft.

38 ft.

31 ft.

24 ft.

37 ft.

30 ft.

22 ft.

15 ft.

WSM2700H

0

1

2

3

56 ft.

46 ft.

34 ft.

32 ft.

42 ft.

36 ft.

28 ft.

18 ft.

WSM2420D*

WSM2480D*

0

1

2

43 ft.

33 ft.

23 ft.

36 ft.

26 ft.

16 ft.

A

4

B

2-1/2

*Foil ducting not allowed

A

WSM2420/80D – GE

®

24” Unitized Spacemaker

®

Washer/Dryer

Advertising
This manual is related to the following products: