12

6. Once the engine has been operating for 10-15 seconds,

slowly return the choke lever back to the right hand side

position. This position will switch the choke ‘off’.

Note:

If the generator stops, move the choke back to the full

left hand side and repeat the starting operation..

Stopping the engine

1. Before stopping, ensure that

no electrical apparatus is

connected to the generator.

2. Press “O” on the engine switch

(6) to ‘stop’ the engine.

3. Turn the fuel tap (4) anti-

clockwise to the ‘off’ position.

Connecting apparatus to the generator - AC

1. Start the engine. Allow the

engine to run for a couple of

minutes to warm up prior to

connecting any apparatus to

the generator. The green power

on light (12) will illuminate

when the generator is

operational and power is

available at the socket.

2. For AC current, plug the power cord into the AC output

socket (10).

Connecting apparatus to the generator - DC

This generator is fitted with a 13.8V DC regulator. The DC

output should only be used for the purpose of charging

suitable lead acid car batteries. Do Not use the DC of the

generator for any other purpose than to charge batteries.
When charging lead acid batteries it is important that you

adhere to these important safety tips:

Do Not

attempt to charge any other type of batteries.

Do Not

use the DC output when 240V output is in use.

Do Not

charge batteries while they are connected to a

vehicle. Make sure they have been totally disconnected

prior to connecting to the generator for recharging.

Do Not

charge the battery in a confined space. The

charge area should be open with adequate ventilation.

Prior to charging, remove the filler caps and top up the

cells with distilled water to the correct level if needed.

To charge your car battery, connect the alligator clips to the

corresponding terminals on your battery. The red lead goes

to the positive (+) terminal and the black lead goes to the

negative (-) terminal. This DC cord has been supplied with

the unit. The generator will charge batteries up to 500CCA

capacity provided the battery is in reasonable condition.

Batteries of larger capacity may charge but will depend on

the condition and also the level of charge in the battery. In

cases where the current exceeds the rating of the Generator,

the circuit breaker on the DC side will open circuit, and will

need to be re set to continue. (Refer to the AC and DC

overload cut out section of this manual).

Note:

Only use the DC leads provided with this generator,

when using the DC output.

WARNING.

Prior to connecting any product to the generator,

check the rating label of the product. The generator is rated

at 650W so if the product being connected is higher than

650W, the protective cut out on the generator may operate

to prevent over load damage to the generator. The generator

will withstand short operation and spikes up to 800W.
It should also be very clearly understood that output voltage

fluctuations will occur when various loads are connected