Gianni Industries Electromechanical Lock User Manual

Electromechanical lock installation instruction

Advertising
background image

Copyright © All Rights Reserved. P-MU-ML-300 Ver. H Publish: 2010.12.24

4 - 1

ML-300
ML-300-SW

Operating Voltage» ML-300: 12 or 24VDC

ML-300-SW: 12~24VDC/AC

Voltage Tolerance» ±10%

Current Draw» ML-300: 280mA/12VDC; 140mA/24VDC

ML-300-SW: 210mA/12VDC; 150mA/24VDC

Version Changeable» Fail-safe or Fail-secure

Operating Temperature» -10~45°C

Humidity» 0~95% non-condensing

Lock bolt sensor switch output» SPDT rated 3A/125VAC

Solenoid testing» Tested to 1,000,000! cycles

Net Weight» ML-300: 800g / ML-300-SW: 815g

Just applicable to vertical installation

Copyright © All Rights Reserved. P-MU-ML-300 Ver. H Publish: 2010.12.24

4 - 4

62mm cylinder for max

42mm door leaf

72mm cylinder for max

52mm door leaf

ш5.0

ш5.0

25

28

150

28

124

250

30

30

5

6

7

8

30

ш5.0

ш5.0

1

2

3

4

Electromechanical Lock
Installation Instruction

Specification

Double Swing Doors

Double swing door

Outswing

Inswing

Version Changeable:
Take out the Screw 1 , release screw 2 , move the
position and then tighten both screws.

“Fail-Safe”

(Power to Lock)

“Fail-Secure”

(Power to Open)

Caution:

Fixing Lug

Allen wrench (1.6mm)

NIB

Lock bolt

Strike Plate

For double swing door For single swing door

Euro profile

key cylinder

Unit:mm

Installation Instructions

Do

or le

af

Doo

r Fr

ame

Door Loop
(Optional)

(Cy

lind

er n

ot inc

lud

ed

)

Align the center line (CL) of the

Alignment CL

Fra

me

Do

or

Le

af

Do

or

Le

af

Cut out mortise holes for the lock

Tighten the fixing lugs with

screws.

Drill and cut the hole for the lock

Connect power cable to the lock

Attach the cover plates for the

Install the cylinder

Fix the strike plate.

Stud bolt Position

Packing Contents

Do not completely remove screw 2 (as marked in the figure)
as the interior solenoid might fall off.

The door loop protects the wiring
from damage at the door hinge.

Attention! Please ensure that the
direction of the template is correct

Do

or F

ram

e

lock body template with the CL of
the door leaf. Ensure the CL of the
strike plate template matches the lock
body CL as closely as possible.

body and strike plate and drill holes
according to the templates.

cylinders as shown in the template.

and test before screwing to the
door leaf.

cylinder lock

For fail-safe mode

For fail-secure mode

Advertising