Receptacles – Generac SVP5000 97193 User Manual

Page 8

Advertising
background image

Generac Portable Products SVP5000 Generator

8

RECEPTACLES

120 Volt AC, 20 Amp Duplex

Receptacles

Each of these receptacles is protected against

overload by 20 Amp push-to-reset circuit breaker.

Use each receptacle to operate 120 Volt, 60 Hz, single

phase loads requiring up to 2,400 (2.4kW) watts of

power at 20 Amps of current (Figure 7).

120/240 Volt AC, 20 Amp Locking

Receptacle

Use a NEMA L14-20P plug with this receptacle.

Connect a 4-wire cord set rated for 250 Volt loads at

20 AC Amps (or greater) (Figure 8). You can use the

same 4-wire cord if you plan only to run a 120 Volt

load.
This receptacle powers 120/240 Volt AC, 60 Hz, single

phase loads and is protected by a 20 Amp push-to-

reset circuit breaker.

120 Volt AC, 30 Amp Locking

Receptacle

Use a NEMA L5-30P plug with this receptacle.

Connect a 3-wire cord set rated for 125 Volt AC loads

at 30 Amps to the plug (Figure 9).

Use this receptacle to operate 120 Volt AC, 60 Hz,

single phase loads requiring up to 3,600 watts

(3.6 kW) of power at 30 Amps. The outlet is protected

by a 30 Amp push-to-reset circuit breaker.

Figure 9 — 120 Volt, 30 Amp Locking Receptacle

Figure 7 — 120 Volt, 20 Amp Duplex Receptacle

Figure 8 — 120/240 Volt, 20 Amp Locking Receptacle

Advertising