General, Site requirements / installation, Installer / supplier details – Stovax 8901 User Manual

Page 2

Advertising
background image

2

GENERAL

Before installation of this product please read these instructions fully.

It is very important to also understand the requirements of the UK Building Regulations (England and Wales – Document J /

Scotland - Part F), along with any local regulations, and working practices that may apply. Should any conflict occur between these

instructions and these regulations then the regulations shall apply.

All electrical connections should meet the requirements of UK Building Regulations

(England and Wales – Document P / Scotland - Part N).

Your local Building Control Office would be happy to advise should questions arise, regarding the requirements of the regulations.

The fireplace should be fitted by a HETAS (GB only) registered installer, or approved by your local building control officer. Your

Stovax dealer should be able to arrange this service for you.

Any gas appliance installation completed in conjunction with the fireplace must be completed by a CORGI registered gas

engineer, in accordance with the manufactures installation instructions. Your Stovax dealer should be able to arrange this service

for you.

Your building insurance company may also require you to inform them that you have installed a new heating appliance, so check

with your insurers that your cover is still valid after installing the fireplace.

When completing the installation and building works you should comply with your responsibilities under the Health and Safety at

Work Acts, and any new regulations, which may be introduced during the lifetime of these instructions.

A faulty installation could cause danger to the inhabitants and structure of the building.

3

SITE REQUIREMENTS / INSTALLATION

Hearth

The constructional and superimposed hearth must meet the

requirements of the Building Regulations for the fire and

surround to be fitted.

Flue

The flue system should meet the requirements of the Building

Regulations for the fire to be fitted and the fuel to be used.

The flue exit from the building should be positioned to comply

with the requirements of the Building Regulations.

Any existing flue should be confirmed as suitable for the new

intended use, as defined in the Building Regulations.

Any existing flue or chimney system must be inspected and

swept by a NACS registered (UK only) chimney sweep, to

confirm that the system is structurally sound and free from any

obstructions.

Suitable access should be provided to enable the collection and

removal of debris.

Provision should be made to sweep and inspect the flue when

the appliance is installed.

No other heating appliances should be connected to, or share,

the same flue or chimney system.

Check the flue draught. This should be done with all windows

and doors closed and any extraction fans in this or adjoining

rooms running at maximum speed.

Note: A guide containing general information on Chimneys and

Flues is obtainable from: -

The British Flue & Chimney Manufacturers’ Association,

FETA

2 Waltham Court, Milley Lane,

Hare Hatch

Reading,

Bucks ,

RG10 9TH

Tel : - 01189 403416 e-mail :- [email protected]

Where a hearth, fireplace, flue or chimney is provided or

extended (including cases where a flue is provided as part

of refurbishment work), information essential to the correct

appliance and use of these should be permanently posted

in the building, to meet Requirement J4 of the Building

Regulations (England and Wales), F3.12 (Scotland).

Fireplace opening

As all fireplaces are different it is not possible to give full details

of the construction of the fireplace opening. But this should be

constructed using ‘best practice’ construction methods using

suitable non-combustible materials.

Additional ventilation

If the fireplace is to be used with Solid fuel, Gas, or Oil products

additional ventilation will be required. This should meet the

requirements of the Building Regulations for the fire to be

fitted and the fuel to be used. This should be provided using a

permanently open air vent, which is positioned so that it is not

liable to be blocked both inside and outside the building.

If any of these checks reveal problems do not proceed with

the fitting of the fireplace until they have been rectified.

Dimensions

Fitting optional insert panel (8904)

The insert panel is fitted to the back of the main front panel

using the 4 fixing screws supplied. This will then allow fitting of

both Stovax and Gazco 16” products.

INSTALLER / SUPPLIER DETAILS

To assist us in any Guarantee claim please complete the following information: -

Stovax dealer the appliance was purchased from

Name: ...........................................................................................................................................................................................

Address: ........................................................................................................................................................................................

.....................................................................................................................................................................................................

Telephone number:.......................................................................................................................................................................

Date installed: ...............................................................................................................................................................................

Model description: ........................................................................................................................................................................

Installation Engineer

Name: ...........................................................................................................................................................................................

Address: ........................................................................................................................................................................................

.....................................................................................................................................................................................................

Telephone number:.......................................................................................................................................................................

Advertising
This manual is related to the following products: