Installation instructions, Commissioning – Stovax 8564 User Manual

Page 17

Advertising
background image

17

INSTALLATION INSTRUCTIONS

COMMISSIONING

1.1

Close all openable doors and windows in the room. Ignite
the stove and operate on maximum for 10 minutes.
Remove the plastic sight plug from the right-hand side of
the stove. Position a lighted smoke match just inside the
draught diverter opening and check that all smoke is drawn
into the opening. Watch through the viewing hole in the
side of the casing. In restricted locations a mirror can be
used. See diagram 1. If there is any doubt, run the stove for
a further 10 minutes, and repeat the test.

1.2

If there are any extractor fans in adjacent rooms, the test
must be repeated with the fans running on maximum and
interconnecting doors open.
IF SPILLAGE PERSISTS, DISCONNECT THE APPLIANCE
AND SEEK EXPERT ADVICE.

For future reference record the installation details on the
Appliance Commissioning Checklist of these instructions.

1. COMMISSIONING

1

Advertising
This manual is related to the following products: