SPECIFICATIONS

GENERATOR

Type ............................................................................. Synchronous
Rotor Insulation ................................................................... Class H
Stator Insulation .................................................................. Class H
Total Harmonic Distortion ......................................................< 3.5%
Telephone Interference Factor (TIF) ..........................................< 50
Alternator Output Leads 3-phase ........................................... 4-wire
Bearings .........................................................................Sealed Ball
Coupling .......................................................................Flexible Disc
Load Capacity (Standby Rating) ............................................40kW*
*

NOTE: Generator rating and performance in accordance with ISO8528-5, BS5514, SAE J1349,

ISO3046 and DIN 6271 Standards. KW rating is based on LPG fuel and may derate with natural

gas.

Excitation System ....................................................................Direct
Generator Output Voltage/kW - 60 Hz

kW

Amp CB Size

120/240V, 1-phase, 1.0 pf (LP)

40

167

175

120/240V, 1-phase, 1.0 pf (NG)

37

154

175

120/208V, 3-phase, 0.8 pf (LP)

40

139

150

277/480V, 3-phase, 0.8 pf (LP)

40

60

70

Generator Locked Rotor KVA Available @ Voltage Dip of 35%
Single-phase or 208V, 3-phase .......................................... 80 KVA
480V, 3-phase .................................................................... 90 KVA

ENGINE

Make ................................................................................... Generac
Model ...................................................................................... V-type
Cylinders and Arrangement ............................................................ 6
Displacement ....................................................................... 3.9 Liter
Bore ...................................................................................... 3.91 in.
Stroke ................................................................................... 3.31 in.
Compression Ratio ...............................................................9.1-to-1
Air Intake System ...............................................Naturally Aspirated
Valve Seats ........................................................... Precision Ground
Lifter Type ......................Overhead Valve Push Rod/Hydraulic Lifter

Engine Parameters
Rated Synchronous RPM ..............................................60 Hz, 1800
HP at rated kW (LP/NG) ...............................................60 Hz, 64/59

Exhaust System
Exhaust Flow at Rated Output 60 Hz .................................. 318 cfm
Exhaust Temperature at Rated Output .................................. 938° F

Combustion Air Requirements (Natural Gas)
Flow at rated power, 60 Hz ................................................. 118 cfm

Governor
Type .................................................................................. Electronic
Frequency Regulation ...................................................Isochronous
Steady State Regulation ......................................................± 0.25%

‹

‹

Engine Lubrication System
Type of Oil Pump ...................................................................... Gear
Oil Filter ............................................... Full Flow Spin-on, Cartridge
Crankcase Oil Capacity ....................................................4 U.S. qts.

COOLING SYSTEM

Type ...................................................Pressurized Closed Recovery
Water Pump .................................................................... Belt Driven
Fan Speed .........................................................................2060 rpm
Fan Diameter .....................................................................22 inches
Fan Mode ..............................................................................Pusher
Air Flow (inlet air including alternator and
combustion air) .......................................................... 2725 ft3/min.
Coolant Capacity ........................................................ (3.0 U.S. gal.)
Heat Rejection to Coolant ..........................................154,000 Btu/h
Maximum Operating Air Temp. on Radiator ..............60° C (150° F)
Maximum Ambient Temperature ................................50° C (140° F)

FUEL SYSTEM

Type of Fuel ......................................... Natural Gas, Propane Vapor
Carburetor ...................................................................... Down Draft
Secondary Fuel Regulator .................................................Standard
Fuel Shut-off Solenoid ........................................................Standard
Operating Fuel Pressure ...................... 5 in. - 14 in. Water Column

Fuel Consumption - ft

3

/hr (Natural Gas/LPV)

Exercise

25%

50%

75%

100%

Cycle

Load

Load

Load Load

82/33 148/59 285/114 397/160 550/221

ELECTRICAL SYSTEM

Battery Charge Alternator ............................................12V, 30 Amp
Static Battery Charger ............................................................2 Amp
Recommended Battery ................................................ 24F 525CCA
System Voltage .....................................................................12 Volts

Voltage Regulator
Type .................................................................................. Electronic
Sensing ........................................................................ Single-phase
Regulation ................................................................................± 1%
Features .................................................V/F Adjustable, Adjustable

Voltage and Gain LED Indicators

Power Adjustment for Ambient Conditions
Temperature Deration
3% for every 10° C above °C ..................................................... 25
1.65% for every 10° above °F .................................................... 77
Altitude Deration
1% for every 100 m above m ................................................... 183
3% for every 1000 ft. above ft. ................................................. 600

Controller .................................................R-100

‹

‹

‹

6-1

Standby Generator Sets

Specifications

GenSpec001 Rev.

D 11/05