SWB-327-AF

49

SWB-327-AF - Belt Drive
Series 300

Wheel Diameter = 27

(686)

Shaft Diameter = 1

11

16

(43)

Outlet Area = 4.19 ft

2

(0.389 m

2

)

^Approximate Unit Weight = 877 lb.

(399 kg)

All dimensions in inches

(millimeters)

For additional discharge positions see page 13
^Weight shown includes largest cataloged Open Drip Proof motor and weatherhood

Maximum BHP at a given RPM = (RPM/671)

3

(Maximum KW at a given RPM = (RPM/740)

3

)

Maximum RPM = 1450
Tip Speed (ft/min.) = RPM x 7.07

(Tip Speed (m/s) = RPM x 0.0359)

Maximum Motor Frame Size = 256T

61

3

4

(1568)

28

1

2

(724)

35

3

4

(908)

3

1

2

(89)

28

3

4

(730)

33

(838)

28

5

8

(727)

46

1

4

(1175)

50

7

8

(1292)

33

(838)

48

1

4

(1226)

52

7

16

(

1332)

30

(762)

21

7

16

(545)

32

(813)

21

1

4

(540)

4

3

16

(106)

CFM

OV

Static Pressure in Inches wg

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

6000

1431

RPM

664

755

833

906

975

BHP

0.86

1.38

1.90

2.44

3.01

Sones / LwiA

10 / 72

11.3 / 74

12.6 / 75

14 / 77

15.6 /79

6700

1599

RPM

719

804

881

946

1013

1075

BHP

1.07

1.63

2.21

2.80

3.41

4.04

Sones / LwiA 11.1 / 74

12.4 / 75

13.8 / 77

15.3 / 79

16.6 / 80

17.4 / 81

7400

1766

RPM

776

856

928

994

1052

1112

1169

1223

BHP

1.31

1.92

2.55

3.21

3.85

4.52

5.22

5.93

Sones / LwiA 12.6 / 76

13.7 / 77

15.3 / 79

16.8 / 80

17.4 / 81

18.2 / 82

19 / 82

19.9 / 83

8100

1933

RPM

834

908

977

1041

1100

1152

1208

1260

1310

BHP

1.59

2.24

2.93

3.64

4.35

5.05

5.79

6.54

7.32

Sones / LwiA 14.2 / 77

15.4 / 79

16.8 / 80

17.7 / 81

18.4 / 82

19.1 / 82

19.8 / 83

21 / 84

22 / 85

8800

2100

RPM

893

963

1028

1089

1147

1200

1247

1299

1348

1395

BHP

1.91

2.61

3.35

4.11

4.88

5.65

6.41

7.21

8.03

8.86

Sones / LwiA 16.1 / 79

17.3 / 81

18.1 / 82

18.7 / 82

19.4 / 83

20 / 83

21 / 84

22 / 85

22 / 85

23 / 86

9500

2267

RPM

953

1019

1081

1139

1194

1247

1295

1340

1387

1433

BHP

2.28

3.03

3.82

4.62

5.45

6.29

7.12

7.94

8.79

9.66

Sones / LwiA 18.3 / 81

19.2 / 82

19.3 / 83

19.7 / 83

20 / 84

21 / 84

22 / 85

23 / 85

23 / 86

24 / 87

10200 2434

RPM

1013

1075

1134

1190

1243

1294

1343

1388

1429

BHP

2.70

3.51

4.33

5.19

6.07

6.95

7.86

8.75

9.63

Sones / LwiA

21 / 83

20 / 83

21 / 84

21 / 84

21 / 84

22 / 85

23 / 86

24 / 86

25 / 87

10900 2601

RPM

1074

1133

1189

1242

1293

1342

1390

1435

BHP

3.17

4.03

4.91

5.81

6.73

7.68

8.62

9.59

Sones / LwiA

22 / 84

22 / 84

22 / 85

22 / 85

23 / 85

23 / 86

24 / 86

25 / 87

11600 2768

RPM

1136

1192

1245

1296

1345

1392

1438

BHP

3.70

4.61

5.54

6.49

7.46

8.46

9.46

Sones / LwiA

23 / 85

23 / 85

23 / 86

23 / 86

24 / 86

25 / 87

25 / 87

12300 2935

RPM

1198

1251

1301

1351

1398

1443

BHP

4.30

5.26

6.24

7.23

8.25

9.29

Sones / LwiA

24 / 86

24 / 87

25 / 87

25 / 87

25 / 87

26 / 87

13000 3102

RPM

1260

1311

1358

1406

BHP

4.96

5.96

7.00

8.04

Sones / LwiA

26 / 87

26 / 88

26 / 88

26 / 88

D

o

no

t

se

le

c

t

to

t

h

e

l

e

ft

o

f

th

is

s

y

s

te

m

c

u

rv

e

Static Pr

essur

e (in. wg)

Volume (cfm X 1000)

Volume (m

3

/hr x 1000)

Static Pr

essur

e (Pa x 100)

0

5

10

15

20

25

0

2

4

6

8

10

12

14

0

2

4

6

8

10

12

14

16

0

1

2

3

4

5

6

610

610

671

671

768

768

845

845

968

968

1147

1147

1313

1313

1450

1450

15

15

10

10

5

5

3

3

2

2

1

1

¾

¾

RPM
HP

Density 0.075 lb/ft

3

Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the
effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA Standard 301. Values shown
are for inlet LwiA sound power levels and inlet hemispherical sone levels for installation type B: Free inlet, Ducted outlet, calculated per AMCA Standard 301. The AMCA
Certified Ratings Seal applies to air performance and LwiA values only.

Advertising
This manual is related to the following products: