Step 8 connect scsi cables, Step 9 set target ids – Gateway ADAC ULTRA2 S466 User Manual

Page 81

Advertising
background image

Chapter 6 Hardware Installation

67

Step 8 Connect SCSI Cables

, Continued

Cable Suggestions System throughput problems can occur if SCSI cable use

is not maximized. You should:

•

you can use cables up to 12 meters for LVD devices.

•

for single ended SCSI devices, use the shortest SCSI cables
(no more than 3 meters for Fast SCSI, no more than 1.5
meters for an 8-drive Ultra SCSI system and no more than 3
meters for a 6-drive Ultra SCSI system),

•

use active termination,

•

avoid clustering the cable nodes,

•

cable stub length should be no more than 0.1 meter (4
inches),

•

route SCSI cables carefully,

•

use high impedance cables,

•

do not mix cable types (choose either flat or rounded and
shielded or non-shielded), and

•

ribbon cables have fairly good cross-talk rejection
characteristics.

Step 9 Set Target IDs

Set target identifiers (TIDs) on the SCSI devices. Each
device in a specific SCSI channel must have a unique TID
in that channel. Non-disk devices (CD-ROM or tapes)
should have unique SCSI IDs regardless of the channel
where they are connected
. See the documentation for each
SCSI device to set the TIDs. The ADAC Ultra2 S466
controller automatically occupies TID 7 in the SCSI
channel. Eight-bit SCSI devices can only use the TIDs
from 0 to 6. 16-bit devices can use the TIDs from 0 to 15.
The arbitration priority for a SCSI device depends on its
TID.

Priority

Highest

Lowest

TID

7

6

5

…

2

1

0

15

14

…

9

8

Important

Non-disk devices (CD-ROM or tapes) should have unique SCSI

IDs regardless of the channel they are connected to.