Example: #FunctionName_param1_param2_param3_param4…\r
Set Preset Routing State
This function enables the user to determine up to 10 routing states to save in
memory.
#PSASRS_param1_param2_param3_param4_param5_param6_param7_
param8_param9\r
Parameter
Name
Value
1
Routing state
[0:9]
2
Input route to MONITOR A
[1:8]
3
Input route to MONITOR B
[1:8]
4
Input route to MONITOR C
[1:8]
5
Input route to MONITOR D
[1:8]
6
Input route to MONITOR E
[1:8]
7
Input route to MONITOR F
[1:8]
8
Input route to MONITOR G
[1:8]
9
Input route to MONITOR H
[1:8]
Set Current Matrix As Routing State
#MSASRS_param1\r
Parameter
Name
Value
1
Routing state
[0:9]
Print Routing State Table
#PRRS\r
Mask Outputs
This function masks the output by by setting the DS HPD to low.
#MASK_param1[_param2][_param3][_param4][_param5]
[_param6][_param7][_param8]\r
Parameter
Name
Value
1 (2-8 optionally)
MONITOR