Technical specifications – Garland ECG User Manual

Page 3

Advertising
background image

2

DO NOT operate the product unless all service and access panels are in place and fastened
properly.

DO NOT attempt to repair or replace any part of this product unless all main power supplies
have been disconnected.

WARNING - to avoid personal injury:

USE EXTREME CAUTION in setting up, operating and cleaning this product to avoid coming
into contact with hot grill surfaces or hot grease. Suitable protective clothing should be worn to
prevent the risk of burns.
NOTE all warning labels and markings on the product, which call attention to further dangers
and necessary precautions.

WARNING – This appliance must not be cleaned with a water jet.

TECHNICAL SPECIFICATIONS

LOADING CHART

LOAD PER PHASE

AMPS PER PHASE

MODEL

TOTAL

kW LOAD

Voltage

X-Y

X-Z

Y-Z

X

Y

Z

Amps

1 phase

8.60

208

2.60

3.00

3.00

23.3

23.3

25.0

41.3

ECG-24R

8.60

240

2.60

3.00

3.00

20.2

20.2

21.7

35.8

12.90

208

4.30

4.30

4.30

35.8

35.8

35.8

62.0

ECG-36R

12.90

240

4.30

4.30

4.30

31.0

31.0

31.0

53.8

17.20

208

5.60

6.00

5.60

48.3

46.6

48.3

82.7

ECG-48R

17.20

240

5.60

6.00

5.60

41.9

40.4

41.9

71.7

21.50

208

6.90

7.30

7.30

59.1

59.1

60.8

103.4

ECG-60R

21.50

240

6.90

7.30

7.30

51.2

51.2

52.7

89.6

25.80

208

8.60

8.60

8.60

71.6

71.6

71.6

124.0

ECG-72R

25.80

240

8.60

8.60

8.60

62.1

62.1

62.1

107.5

EXTERIOR DIMENSIONS

MODEL

HEIGHT

WIDTH

DEPTH

WEIGHT

mm

ins

mm

ins

mm

ins

kg

Lb.

ECG-24R

905

35 5/8

610

24

889

35

120

265

ECG-36R

905

35 5/8

914

36

889

35

181

400

ECG-48R

905

35 5/8

1219

48

889

35

227

500

ECG-60R

905

35 5/8

1524

60

889

35

272

600

ECG-72R

905

35 5/8

1829

72

889

35

318

700

ELECTRICAL SUPPLY

Before attempting the electrical connection, the rating plate should be checked to ensure that the
equipment’s electrical characteristics agree. On Electric Chain Griddles, the supply entrance is
located at the rear of the main bottom. The supply terminal block is accessible from the front.

ELECTRICAL SUPPLY

CONTINUED

The electrical supply must be adequate for the voltage, phase and current marked on the rating
plate.