Gb 5. storage, Maintenance – Gardena Pressure Tank Unit D-89070 Ulm User Manual

Page 6

Advertising
background image

15

GB

5. Storage

Storage:

If there is a risk of frost, the Pressure Tank Unit must be stored
where it will not become frozen.

1. Unplug the mains connection for the

pump.

2. Turn the rotary switch

ቩ to FILL.

3. Unscrew the drain screw

ቤ.

The Pressure Tank Unit will drain down.

4. Store the pressure tank unit in a dry,

frost-free place.

Store out of the reach of children.

Disposal:

The unit must not be disposed of with normal household waste but

(in accordance with

must be disposed of in accordance with local environmental

directive 20002/96/EC)

regulations.

6. Maintenance

DANGER ! Electric shock !
Pull out mains plug before undertaking any maintenance.

Clean suction filter:

1. The rotary switch

must be set to RUN.

If necessary turn the rotary switch

ቩ to RUN.

2. If necessary, close all the shut-off devices on the intake side.

3. Unscrew and remove cover

ቨ of the filter chamber.

4. Draw out filter unit

ቭ ቮ

vertically upwards.

5. Hold beaker

ቭ firmly, turn

filter

ቮ anti-clockwise A and

draw out B (bayonet fitting).

6. Clean beaker

ቭ under running

water and clean the filter

e.g. with a soft brush.

7. Refit filter again in reverse

order.

©

©

©

©

©

©

©

©

©

©

Advertising