Specification Revised 3/08

110179

ZISW/B480DR – GE Monogram 48" Built-In Side-by-Side Refrigerator

with Dispenser and Water Filter

Space is the first consideration when planning the installation.

The cutout depth must be 24"

The refrigerator will project forward, slightly beyond adjacent

cabinetry, depending on your installation.

The cutout depth beneath a soffit

When installed beneath a soffit, the soffit cannot exceed the

24" installation depth shown. The top case trim overlaps the

bottom of the soffit.

Electrical

A 115V, 60Hz., 15 or 20 amp power supply is required. An

individual properly grounded branch circuit or circuit breaker

is recommended. Install a properly grounded 3-prong electrical

receptacle recessed into the back wall. Electrical must be

located on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.

Water Line

All models are equipped with an automatic icemaker. The

water line can enter the opening through the floor or back

wall. Route 1/4" O.D. copper tubing or GE QuickConnect

kit between the cold water line and the water connection

location. The copper tubing should be long enough to extend

to the front of the refrigerator. The installation of an easily

accessible shut-off valve in the water line is required.

Door Swing Clearances

The installation must allow for clearances to adjacent walls or

cabinets. These refrigerators are equipped with a 2-position

door stop. The factory-set 130° door swing can be adjusted to

90° if clearance to adjacent cabinets or walls is restricted.

Allow minimum clearances for freezer door and fresh food

door for a full 130° door swing and to allow for pan removal.
• 4" minimum clearance is required when door swing is

adjusted to 90°. If the 90° door stop position is used, pan

access is maintained, but pan removal is restricted.

• See door swing illustrations to determine interaction with

adjacent cabinets or countertops.

Installation Information: Before installing, consult

installation instructions packed with product, or online at

Monogram.com, for current dimensional data.

Listed by

Underwriters

Laboratories

As an EnErgy StAr

®

partner, gE has determined

that this product meets the

EnErgy StAr guidelines

for energy efficiency.

For answers to your Monogram,

®

gE Profile

or

gE

®

appliance questions, visit our website at

gEAppliances.com or call

gE Answer Center

®

service, 800.626.2000.

* Shipping height.

The refrigerator

can be adjusted to

fit into a cutout that

is 83-1/2" min. to

84-1/2" max. height

Note that the top

case trim at the

front is 1/2" higher

and will overlap

upper cabinetry or

soffit. Use leveling

legs and wheels for

a maximum 1" height

adjustment.

*84" From

Floor to

Top Frame

48"

Frame to Frame

47"

Case Width

*83-1/2"

at

Rear

25-3/8

26-7/8"

including

handle

23-7/8"

Behind

Frame

90

° Door Swing

4" Min.

to Wall

28-5/8"

20"

130

° Door Swing

15"

Dimensions and Clearances (in inches)
The Installation Space

*Finished Width

6"

5"

Electrical

Area

84-1/2" max

83-1/2" min

Finished

Opening

75" From Floor

to Bottom

of Electrical

Area

24"

5"

5"

3-1/2"

Water Supply

3-1/2"

36" Models 12"

42" Models 18"

48" Models 20"

696Dia15