Pre-start routine – Global Machinery Company 50L User Manual

Page 10

Advertising
background image

10

Oil

WARNING.

The air compressor must be filled with oil

before first use.
To prevent possible spillage of oil during transport, the

compressor oil is supplied in a separate container. It must

be added to the compressor before turning the compressor

on. Failure to add the oil will cause non-repairable damage

to the compressor and will void the warranty.
1. Remove the plastic oil filling plug (14) located on the top

of the crank case of the compressor housing.

2. Use the oil supplied to fill the crank case until the oil level

as seen in the oil level glass (16) is up to the mid point of

the red circle.

3. Replace the oil filling plug (14). Ensure the plug is fully

fitted and firmly in position.

Air filter

WARNING.

The air filter must be added before use.

Failure to fit the air filter will

damage the compressor and will

void the warranty.
1. To fit the air filter (15) you

need to locate the inlet

hole on the right side of the

compressor housing then

carefully hand tighten the

thread of the air filter in a

clockwise direction until tight.

Pre-start routine

1. Ensure that the location for the compressor is clean,

dry and well ventilated.

2. Ensure the crank case has been filled with oil and is

at the correct level, and the air filter has been fitted.

3. Open the regulated output

valve (6). Open the valve by

rotating the air tap (17) so it is

in line with the air outlet (refer

to the OPEN picture).

To close the valve, rotate the

air tap so it is facing to the right

or the left side of the air valve

(refer to the CLOSED picture).

4. Start the compressor by

following the procedure in

the section “To start and stop

the compressor”. For the first

time of operation, run the

compressor for 10 minutes

with no load and with the

outlet valve open to ensure all

parts are well lubricated.

WARNING.

Be aware that

pressurised air will be discharged from the outlet and care

should be taken that this discharge is not directed towards

you the operator, or other persons within the area.

To start & stop the compressor

1. Check the rating label on the compressor indicates

230V–240V.

2. Plug in the mains cable of the compressor to a standard

240V household power point and turn on.

3. To start the compressor, push the On/Off lever (3)

downward so that the lever is in the horizontal position.

OPEN

CLOSED