BLOWER PERFORMANCE DATA

6

3

4

Normal*

+10%

Air flow Adjust Taps (*indicates factory setting)

-10%

Normal

OFF

OFF

OFF

OFF

ON

ON

ON

ON

3

4

3

4

3

4

Thermostat "Fan Only" Mode

During "Fan Only" operations, the CFM output is 30% of the maximum CFM capability.

CFM Trim Adjust

Minor adjustments can be made through the dipswitch combination of 3-4.

Locate the blower speed selection DIP switches on the integrated control module. Select the desired
“cooling” speed tap by positioning switches 1 and 2 appropriately. Select the desired “adjust” tap by
positioning switches 3 and 4 appropriately. Refer to the following figure for switch positions and their
corresponding taps. Verify CFM by counting the number of times the green CFM LED blinks.

1

2

3

4

5

6

400

600

OFF

OFF

OFF

OFF

OFF

OFF

540

800

ON

OFF

ON

OFF

ON

OFF

670

1000

OFF

ON

OFF

ON

OFF

ON

800

1200

ON

ON

ON

ON

ON

ON

670

1000

OFF

OFF

OFF

OFF

OFF

OFF

800

1200

ON

OFF

ON

OFF

ON

OFF

940

1400

OFF

ON

OFF

ON

OFF

ON

1070

1600

ON

ON

ON

ON

ON

ON

800

1200

OFF

OFF

OFF

OFF

OFF

OFF

1070

1600

ON

OFF

ON

OFF

ON

OFF

1200

1800

OFF

ON

OFF

ON

OFF

ON

1340

2000

ON

ON

ON

ON

ON

ON

ADJUST SELECTION

SWITCHES

PROFILE SELECTION

SWITCHES

MBVC1200

MBVC1600

MBVC2000

COOL SELECTION

SWITCHES

MODEL

LOW STAGE

COOL

HIGH STAGE

COOL

HTR kW

MBVC1200*

MBVC1600*

MBVC2000*

SWITCH

9

SWITCH

10

SWITCH

11

3

600

800

800

ON

ON

ON

5

600

800

800

ON

ON

OFF

6

635

800

800

ON

OFF

ON

8

740

1000

1000

ON

OFF

OFF

10

1000

1000

1200

OFF

ON

ON

15

1400

1500

1500

OFF

ON

OFF

20

NR

NR

2000

OFF

OFF

ON

21

NR

NR

NR

ON^

ON^

ON^

^ Factory setting