Installation instructions, Installation, Installation of the appliance – Stovax PR0696 User Manual

Page 13

Advertising
background image

13

3

AR1154

5.4 Gas pipe entry must come through the right hand side of

the box. The rubber seal must be cut using a sharp knife to

allow the isolating elbow to pass through it. Ensure the

rubber is not damaged when doing this.

A means of isolation is provided with the appliance. This

must be fitted to the supply pipe prior to installing the

firebox.

6.INSTAllATION OF ThE APPlIANCE

6.1 Ensure that the fireplace opening is in compliance with the

requirements of section 2 Site Requirements then proceed

as follows:

A) CABlE RETENTION METhOD

6.2 Mark the position of the 4 fixing holes on the rear of the

fireplace opening and drill the holes using a No. 12 masonry

drill bit. Insert the 4 fibre rawl plugs and screw the eyebolts

in as far as possible leaving the eye horizontal. See diagram 4.

4

AR1205

AR1204

Hotbox

Convector

75 75

75 75

465

48

328

24

6.3 Pass the 2 cables through the holes in the bracket on the

back of the firebox and pull taut so that the stop ends sit

tightly against the top of the bracket. See diagram 5.

5

AR1155

AR1156

Hotbox

Convector

6.4 Pass the cables vertically through the 2 sets of eyebolts and

thread the ends through the holes in the lower back of the

firebox. Pass the gas supply pipe through the hole in the

rubber seal (refer to section 5.2) and push the appliance into

place.

6.5 Thread the cables through the tensioner bolts and push the

threaded portions through the holes in the firebox so that

the lock nut sits against the back wall (ensure that the nut is

screwed fully up to the head of the tensioner to allow

maximum adjustment).

6.6 Slide the locking nipples onto the cables, pull the cables taut

and tighten the locking screw. Adjust the lock nuts using a

10mm spanner until the silicone sealing strip forms a tight

seal between the fireplace opening and the firebox flange.

See diagram 6.

6

AR1157

6.7 Coil up the surplus cable and locate in the back of the

fire box.

NEvER ShORTEN ThE CABlES, ThEY WIll BE REQUIRED

WhEN SERvICING ThE APPlIANCE.

INSTAllATION INSTRUCTIONS

INSTAllATION

Advertising