GB

5. Storage

Storage:

➜ Clean and store the pump in a frost-free place before the first

frost arrives.

Disposal:

The product must not be added to normal household waste.

(in accordance with

It must be disposed of in line with local environmental regulations.

6. Cleaning

The GARDENA should not require regular maintenance.

Flushing the pump:

After pumping pumped chlorinated swimming pool water or other
liquids leaving residues, the pump should be rinsed with clear
water.

Cleaning the suction

WARNING ! Electric shock !

Risk of injury due to electric shock.
Disconnect the pump from the mains before

cleaning the suction base and feed impeller.

1. Unscrew the cross-head screws

ቪ and remove the suction

base

ቩ from the pump.

2. 6000 SP: Press snap hooks

k

s together and remove safety

cover

ቨ from suction foot ቩ and clean.

3. Clean suction foot

ቩ and impeller ቫ.

4. Refit suction foot

ቩ and screw in the cross-head screws ቪ

again. During this, ensure that the sealing ring

ቭ is seated

correctly.

5. 6000 SP: Reinsert the safety cover

ቨ in the suction foot ቩ

again.

For safety reasons a damaged feed impeller

can only be

exchanged by the GARDENA Service Centre.

7. Troubleshooting

WARNING ! Electric shock !

Risk of injury due to electric shock.
Disconnect the pump from the mains before

rectifying faults.

Problem

Probable cause

Remedy

Pump is running,

Air cannot escape as

➜ Open pressure line

but oes not deliver.

pressure line is closed.

(e.g. kinked pressure pipe).

Air locks in the suction base.

➜ Wait for max. 60 seconds

until the pump deaerates
automatically over the vent
valve. If necessary, switch
off and start it again.

©

©

©

©

©