Electrical supply, Electrical supply connection, Siting – Garland E22-36 User Manual

Page 3: Ventilation, General installation procedure, Commissioning

Advertising
background image

Part # 4517056 (10/04)

Page 3

Electrical Supply:

Before attempting the electrical connection, the rating

plate should be checked to ensure the equipment’s electrical

characteristics and the supply electrical characteristics agree.

On griddles the supply entrance is located at the rear or

alternatively on the main bottom. The supply terminal block

is accessible from the front. The electrical supply must be

adequate for the voltage, phase and current marked on the

rating plate.
Note: A means of disconnection from the supply having

a contact separation of at least 3 mm in all poles must be

incorporated in the fixed wiring.
WARNING: THIS APPLIANCE MUST BE EARTHED

Electrical Supply Connection:

For supply connection, use wire suitable for 75°C (167°F).
A bottom knockout is provided near the front left side of the

unit, located behind the control panel. To view the knockout,

loosen the four acorn nuts and remove the control panel. The

terminal block is also located in this area.
The rear supply cable entrance is located on the right side

when facing the rear of the unit. The cable is fed towards the

front through the wire way.

Siting:

The base on which the griddle is to be sited must be capable

of adequately supporting the weight of the appliance and

any ancillary equipment. Once in position, check that the

equipment is level, both front and back and side to side. Adjust

if necessary.

INSTALLATION

Ventilation:

This product is to be installed under a ventilation hood.
Proper operation of exhaust fans (proper speed, rotation and

adjustment) is essential. In addition a make-up air system for

the kitchen to supply fresh air is recommended.
Any ventilation system will break down if improperly

maintained. The duct system, the hood, and the filters must

be cleaned on a regular basis and kept grease free.

General Installation Procedure:

1. Carefully remove the unit from the crate. All packing

material must be removed from the unit.

2. All griddles are shipped from the factory with leveling

feet.

3. Place the griddle in the desired location and level from

side to side and back to front.

4. Adequate clearance must be provided for servicing,

ventilation and proper operation. The product must be

kept free from combustible material.

Commissioning:

1. Ensure all circuit breakers located in the lower

compartment are set to the ON (1) position.

2. Ensure that all controls are in the off position and turn

on the main electrical supply.

3. Operate the grill in accordance with the instructions.
4. Check that the product functions correctly and that the

voltage supply to the unit does not drop by more than

5% when all sections are operated simultaneously.

When the operation has been checked, hand this instruction

manual to the user or purchaser for retention. Instruct them

in the efficient and safe operation of the appliance.

Advertising